Related Experiment Video
Updated: Aug 22, 2025

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Atrial fibrillation detection using insertable cardiac monitor after stroke: A real-world cohort study
Jean J Noubiap1,2, Gijo Thomas1, Melissa E Middeldorp1,2
1Centre for Heart Rhythm Disorders, University of Adelaide, Adelaide, Australia.
Objective:
This study aimed to report the real-world atrial fibrillation (AF) diagnostic yield of the implantable cardiac monitor (ICM) in patients with stroke or transient ischemic attack (TIA), and compare it to patients with an ICM for unexplained syncope.
Methods:
We used patient data from device clinics across the United States of America with ICM remote monitoring via PaceMate™, implanted for stroke or TIA, and unexplained syncope. Patients with known AF or atrial flutter were excluded. The outcome was AF lasting ≥2 min, adjudicated by International Board of Heart Rhythm Examiners certified cardiac device specialists.
Results:
We included a total of 2469 patients, 51.1% with stroke or TIA (mean age: 69.7 [SD: 12.2] years, 41.1% female) and 48.9% with syncope (mean age: 67.0 [SD: 17.1] years, 59.4% female). The cumulative AF detection rate in patients with stroke or TIA was 5.5%, 8.9%, and 14.0% at 12, 24, and 36 months, respectively. The median episode duration was 73 (interquartile range: 10-456) min, ranging from 2 min to 40.9 days, with 52.3%, 28.6%, and 4.4% of episodes lasting at least 1, 6, and 24 h, respectively. AF detection was increased by age (adjusted hazard ratio [for every 1-year increase]: 1.024, 95% confidence interval: 1.008-1.040; p = .003), but was not influenced by sex (p = .089). For comparison, the cumulative detection rate at 12, 24, and 36 months were, respectively, 2.4%, 5.2%, and 7.4% in patients with syncope.
Conclusion:
Patients with stroke or TIA have a higher rate of AF detection. However, this real-world study shows significantly lower AF detection rates than what has been previously reported.
More Related Videos
08:10Estimating Bilateral Atrial Function by Cardiovascular Magnetic Resonance Feature Tracking in Patients with Paroxysmal Atrial Fibrillation
Published on: July 20, 2022
05:03Patient Directed Recording of a Bipolar Three-Lead Electrocardiogram using a Smartwatch with ECG Function
Published on: December 11, 2019
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Dysrhythmias V: Evaluating Dysrhythmias
Cardiopulmonary Resuscitation III: AED Use