Methods to expose subsurface objects of interest identified from 3D imaging: The intermediate sample preparation
R L Mitchell1,2, T Dunlop1, T Volkenandt3
1Advanced Imaging of Materials (AIM) Core Facility, Faculty of Science and Engineering, Swansea University, Bay Campus, Swansea, UK.
Abstract:
The correlative imaging workflow is a method of combining information and data across modes (e.g. SEM, X-ray CT, FIB-SEM), scales (cm to nm) and dimensions (2D-3D-4D), providing a more holistic interpretation of the research question. Often, subsurface objects of interest (e.g. inclusions, pores, cracks, defects in multilayered samples) are identified from initial exploratory nondestructive 3D tomographic imaging (e.g. X-ray CT, XRM), and those objects need to be studied using additional techniques to obtain, for example, 2D chemical or crystallographic data. Consequently, an intermediate sample preparation step needs to be completed, where a targeted amount of sample surface material is removed, exposing and revealing the object of interest. At present, there is not one singular technique for removing varied thicknesses at high resolution and on a range of scales from cm to nm. Here, we review the manual and automated options currently available for targeted sample material removal, with a focus on those methods which are readily accessible in most laboratories. We summarise the approaches for manual grinding and polishing, automated grinding and polishing, microtome/ultramicrotome, and broad-beam ion milling (BBIM), with further review of other more specialist techniques including serial block face electron microscopy (SBF-SEM), and ion milling and laser approaches such as FIB-SEM, Xe plasma FIB-SEM, and femtosecond laser/LaserFIB. We also address factors which may influence the decision on a particular technique, including the composition, shape and size of the samples, sample mounting limitations, the amount of surface material to be removed, the accuracy and/or resolution of peripheral parts, the accuracy and/or resolution of the technique/instrumentation, and other more general factors such as accessibility to instrumentation, costs, and the time taken for experimentation. It is hoped that this study will provide researchers with a range of options for removal of specific amounts of sample surface material to reach subsurface objects of interest in both correlative and non-correlative workflows.
More Related Videos
10:25Dual-color Correlative Light and Electron Microscopy for the Visualization of Interactions between Mitochondria and Lysosomes
Published on: September 27, 2024
11:19Multimodal Hierarchical Imaging of Serial Sections for Finding Specific Cellular Targets within Large Volumes
Published on: March 20, 2018
Related Concept Videos
Preparation of Samples for Electron Microscopy
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
