Tympanostomy tube placement for pressure-sensitive vertigo
Mehdi Abouzari1, Karen Tawk1, Cecilia H H Nguyen1
1Department of Otolaryngology-Head and Neck Surgery University of California Irvine California USA.
Objective:
To evaluate tympanostomy tube placement in patients with pressure-sensitive vertigo.
Methods:
Retrospective case series.
Results:
Six patients with pressure-sensitive vertigo reported resolution of their vertigo and other vestibular symptoms after placement of the tympanostomy tubes. All recurrences of symptoms were due to either extrusion or plugging of the tubes. All patients fulfilled the criteria for vestibular migraine. None of the patients had superior canal dehiscence on imaging or precedent event that triggered the problem, and all had a negative fistula test.
Conclusion:
Tympanostomy tube placement should be considered in selected patients with vertigo exacerbated by seemingly small changes in atmospheric pressure (e.g., just prior to thunderstorms, air travel, or travel to the mountains). By eliminating the capability of the tympanic membrane to sense changes in pressure with a tube, patients with pressure-induced vertigo (in the absence of perilymph fistula or superior canal dehiscence) may have relief of their symptoms.
Related Concept Videos
Anatomy of the Ear
Equilibrium and Balance
Tracheostomy: Procedure and Tubes
Tracheostomy tubes can be made of semiflexible plastic (polyurethane or silicone), rigid plastic, or metal, and they come in...
The Vestibular System
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...