Impact of drainless neck dissection on surgical outcome: a matched case-control study
Oded Cohen1,2, Pnina Hirsh3, Ophir Winder3
1A.R.M. Center of Otolaryngology Head and Neck Surgery, Assuta Medical Centers, Affiliated With Ben-Gurion University of the Negev, 20 HaBarzel Street, Tel Aviv, Israel. odedco@clalit.org.il.
Summary
Drainless lateral neck dissection (ND) using fibrin sealant (FS) is safe and feasible. This technique did not significantly increase post-operative seroma or infection rates in patients undergoing non-mucosa violating surgeries.
Area of Science:
- Surgical Oncology
- Head and Neck Surgery
- Surgical Innovation
Background:
- The safety of drainless lateral neck dissection (ND) requires further investigation.
- Fibrin sealant (FS) is a potential adjunct for achieving drainless ND.
Purpose of the Study:
- To evaluate the safety and outcomes of drainless lateral neck dissection (ND) utilizing fibrin sealant (FS).
- To compare post-operative complications between drainless ND and conventional ND.
Main Methods:
- Retrospective, matched case-control study at a single academic institution.
- Compared patients undergoing drainless ND with FS to controls matched for age, sex, BMI, laterality, and dissection extent.
- Included an additional analysis for thyroid cancer patients undergoing lateral ND (levels II-IV).
Main Results:
- 118 patients (42 drainless ND, 76 controls) included; no significant differences in pre-operative characteristics or dissection extent.
- No significant differences in post-operative infections, seroma, aspirations, or antibiotic use between groups.
- Analysis of 23 drainless ND for thyroid cancer showed no significant increase in seroma or infection compared to controls, confirmed by multivariate analysis.
Conclusions:
- Drainless lateral neck dissection (ND) using fibrin sealant (FS) is feasible and safe for non-mucosa violating surgeries.
- This technique does not significantly increase the risk of post-operative seroma or associated complications.
- Findings support the use of drainless ND with FS as a safe alternative to conventional methods.