Related Experiment Video
Updated: Aug 14, 2025

Laser Doppler Perfusion Imaging in the Mouse Hindlimb
Published on: April 18, 2021
Pulse Amplitude Measured with a Portable Laser Doppler Flowmeter Is Useful for Screening of Dialysis Patients for
Makoto Saito1, Hiroomi Jingu1, Hidefumi Osawa2
1Department of Clinical Engineering, Public Tomioka General Hospital, Tomioka, Gunma, Japan.
Abstract:
Objective: The objective of this study was to use a portable laser Doppler flowmeter (LDF) to measure the toe blood flow and pulse amplitude as a screening test for peripheral arterial disease (PAD) in dialysis patients and compare the diagnostic abilities of the aforementioned parameters measured using an LDF with those of the ankle-brachial index (ABI) and toe brachial index (TBI). Methods: The 14 patients in this retrospective study received maintenance hemodialysis (HD). We measured the blood flow and pulse amplitude on the ventral side of the first toe with a portable LDF while the patients were undergoing an HD session. The correlations between the blood flow/pulse amplitude in the toe and the ABI/TBI were examined. Results: Both the ABI and TBI had a strong correlation with pulse amplitude. The sensitivity and specificity of the pulse amplitude measured with the LDF for detecting PAD in HD patients as determined by a receiver operating characteristic curve analysis were 1.00 and 0.88, respectively. Conclusion: Measuring the pulse amplitude in the toe with a portable LDF may serve as a simple and useful screening test for PAD in HD patients.
Related Concept Videos
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Pulse
The pulse serves as a clinical...
Pulse Assessment Sites

