Related Experiment Video
Updated: Aug 14, 2025

Iris Fixation via External Pentagram Suturing
Published on: May 5, 2022
Assessment of Iris Trabecular Contact in Eyes with Gonioscopic Angle-Closure
Xiulan Zhang1, Philip Yawen Guo2, Chen Lin3
1State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangdong Provincial Key Laboratory of Ophthalmology and Visual Science, Guangdong Provincial Clinical Research Center for Ocular Diseases, Guangzhou, PRC.
Purpose:
To investigate the extent of iris trabecular contact (ITC) measured by anterior segment OCT (AS-OCT) and its association with primary angle-closure (PAC) and PAC glaucoma (PACG) in eyes with gonioscopic angle-closure and to determine the diagnostic performance of ITC for detection of gonioscopic angle-closure.
Design:
Multicenter, prospective study.
Participants:
A total of 119 healthy participants with gonioscopic open-angle and 170 patients with gonioscopic angle-closure (94 with PAC suspect and 76 with PAC/PACG) were included.
Methods:
One eye of each subject was randomly selected for AS-OCT imaging. Angle-opening distance (AOD500) and trabecular iris space area (TISA500) were measured every 10° for 360°. Two criteria of ITC500 were examined: (1) AOD500 = 0 mm and (2) TISA500 = 0 mm2. The association between the extent of ITC500 and PAC/PACG in eyes with gonioscopic angle-closure was analyzed with logistic regression analysis.
Main Outcome Measures:
Sensitivity and specificity of ITC500 for detection of gonioscopic angle-closure; odds ratio (OR) of PAC/PACG.
Results:
The sensitivity of ITC500 ≥ 10° for detection of gonioscopic angle-closure ranged from 82.4% (AOD500 = 0 mm) to 84.7% (TISA500 = 0 mm2), and the specificity was 85.7% (for both AOD500 = 0 mm and TISA500 = 0 mm2). The extent of ITC500 determined by AS-OCT, not cumulative gonioscopy score (i.e., the sum of the modified Shaffer grades over 4 quadrants), was associated with the odds of PAC/PACG in eyes with gonioscopic angle-closure; the odds of PAC/PACG increased by 5% for every 10° increase in ITC500 (OR, 1.051, 95% confidence interval [CI], 1.022-1.080 for AOD500 = 0 mm; OR, 1.049, 95% CI, 1.022-1.078 for TISA500 = 0 mm2). Axial length and anterior chamber depth were not associated with PAC/PACG in eyes with gonioscopic angle-closure (P ≥ 0.574).
Conclusions:
A greater extent of ITC measured by AS-OCT, not angle-closure determined by gonioscopy, was associated with a greater odds of PAC/PACG in eyes with gonioscopic angle-closure.
Related Concept Videos
Angle Closure Glaucoma: Treatment
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...

