Related Experiment Video
Updated: Aug 12, 2025

Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
Case report: Fatal systemic embolism caused by early prosthetic valve endocarditis after Bentall surgery
Shaofeng Wu1, Xin Wang1, Weidong Ren1
1Department of Ultrasound, Shengjing Hospital of China Medical University, Shenyang, China.
Abstract:
Prosthetic valve endocarditis (PVE) is a rare but dangerous complication of Bentall surgery and Staphylococcus epidermidis PVE involving multiple valves simultaneously during the early postoperative period has not been reported. A 42 year old patient admitted to intensive care unit with fever 1 month after aortic valve replacement (Bentall procedure). Echocardiography was of great diagnosis value and suggested large, mobile vegetations on both the prosthetic aortic valve and native tricuspid valve. The presence of Staphylococcus epidermidis was revealed by multiple blood cultures. Surgery was not performed because of the history of aortic valve replacement 1 month ago. He developed acute right femoral artery thromboembolism, multiple cerebral infarction and splenic infarction during hospitalization and died of cerebral infarction after being discharged. This case underlines that patients with early PVE may have poor prognosis and fatal systemic embolism should be aware of in PVE patients with large vegetations present with dyskinesia, abdominal pain, and limb numbness. The timely echocardiography and vascular ultrasound are primary and reliable diagnostic methods in this scenario.
More Related Videos
07:50An In Vitro Model of a Parallel-Plate Perfusion System to Study Bacterial Adherence to Graft Tissues
Published on: January 7, 2019
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022