Related Experiment Video
Updated: Aug 10, 2025

Monitoring the Wall Mechanics During Stent Deployment in a Vessel
Published on: May 8, 2012
Structural Stability Monitoring of Model Test on Highway Tunnel with Lining Backside Voids Using Dynamic and Static
Chaofei Du1, Chuanbo Zhou1, Nan Jiang1
1Faculty of Engineering, China University of Geosciences, Wuhan 430074, China.
Abstract:
Voids behind a lining may develop due to insufficient backfilling, poor workmanship, water erosion or gravity. They affect the interaction between the surrounding rock and lining and even cause instability of the lining structure. To ensure the safe operation of tunnels, it is very important to study the influence of voids behind the lining of the lining structure. In this paper, a laboratory model of a tunnel lining was established by taking the voids behind the lining of the Wushan Tunnel as an example. By changing the position and size of the voids, the corresponding stress variation law of the lining was obtained, and the influence of the voids behind the lining on the structural stability of the highway tunnel was analyzed. The experimental results showed that the voids behind the lining led to an increase in the stress near the voids, especially the voids at the vault. The circumferential stress and axial stress increased with increasing void depth and length, and the increase was greater with increasing void depth than increasing length; that is, the void depth had a greater effect on the lining stress. When the vault void depth was 30 mm, the axial tensile stress of the vault was 0.281 MPa, and the maximum increase was 178.2% compared with that without voids. The safety factors at different lining positions, from large to small, are: arch foot > spinner > arch top > arch waist. In the processes of lining operation and maintenance, special attention should be given to the treatment of voids behind the lining, especially deep voids.
Related Concept Videos
Measurements of Strain
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Non-destructive Tests for Concrete Strength
Three-Dimensional Analysis of Strain
True Stress and True Strain
In contrast, true stress offers a more precise portrayal. It is computed by dividing the...
Thermal Strain