Related Experiment Video
Updated: Aug 9, 2025

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Fracture resistance of CAD/CAM blocks cemented on dentin using different cementation strategies
Munlika Anuntasainont1, Nanthiphorn Po-Ngam1, Anne-Katrin Lührs2
1Department of Operative Dentistry and Endodontics, Faculty of Dentistry, Mahidol University, Bangkok, Thailand.
Purpose:
To determine whether the fracture resistance of computer-aided design/computer-aided manufacturing (CAD/CAM) resin-based composites and polymer-infiltrated ceramic network materials cemented on dentin is influenced by the restoration thickness and composite cement application strategy.
Methods:
Disc-shaped specimens (Ø = 7 mm) of 0.8 mm and 1.5 mm thicknesses were milled from two CAD/CAM materials: resin-based composite (RBC, Cerasmart 270) and polymer-infiltrated ceramic network (PICN, Vita Enamic). The discs (n = 8 per group) were cemented on flattened dentin using three different cementation strategies: 1) self-adhesive composite cement (RelyX U200) in light-curing mode (LC-SAC), 2) universal adhesive (Single Bond Universal) with composite cement (RelyX Ultimate) in auto-curing mode (AC cement), and 3) adhesive and composite cement as in 2) but in light-curing mode (LC cement). The restorative surface was indented perpendicularly with a compressive load using a universal testing machine until fracture. The fracture resistance (N) of RBC and PICN was separately analyzed using two-way ANOVA and Tukey's post-hoc test (α = 0.05).
Results:
The fracture resistance of each material was significantly influenced by the material thickness and cementation strategy (P < 0.05). Irrespective of the material type and cementation strategy, thicker materials exhibit higher fracture resistance. For RBC, the fracture resistance of the LC cement group was significantly higher than that of AC cement only at 0.8 mm thickness. For PICN, the LC-cement cementation strategy produced superior fracture resistance, regardless of the restoration thickness.
Conclusions:
The fracture resistance of Cerasmart 270 was higher for the thicker material; the fracture resistance of LC cement was higher than that of AC cement at 0.8 mm thickness cemented to dentin. In comparison, LC cement showed the highest fracture resistance for Vita Enamic for both material thicknesses.
Related Concept Videos
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Brick Durability, Strength, and Appearance
Reinforced Brick Masonry
To fortify brick walls...
Masonry
The process of building with masonry is hands-on and can be executed with basic tools....
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Microcracking in Concrete

