Cusp-overlap technique during TAVI using the self-expanding Portico FlexNav system.
Lluis Asmarats1, Lola Gutiérrez-Alonso1, Luis Nombela-Franco2
1Servicio de Cardiología, Hospital de la Santa Creu i Sant Pau, Instituto de Investigación Biomédica Sant Pau, Barcelona, Spain; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Spain.
The cusp overlap technique (COT) during Portico transcatheter aortic valve implantation (TAVI) leads to deeper valve placement and fewer conduction disturbances. This technique improves outcomes for patients undergoing TAVI with intra-annular valves.
Area of Science:
- Cardiovascular Medicine
- Interventional Cardiology
- Medical Devices
Background:
- Transcatheter aortic valve implantation (TAVI) is a common procedure for aortic stenosis.
- Conduction disturbances (CD) are a known complication after TAVI, particularly with self-expanding supra-annular devices.
- Limited data exist on the efficacy of the cusp overlap technique (COT) with intra-annular valves like the Portico system.
Purpose of the Study:
- To evaluate the feasibility and effectiveness of the cusp overlap technique (COT) during Portico transcatheter aortic valve implantation (TAVI).
- To determine if COT improves valve implantation depth and reduces new-onset conduction disturbances (CD).
Main Methods:
- A retrospective and prospective study involving 85 patients undergoing TAVI with the Portico FlexNav system.
- Patients were divided into two groups: standard 3-cusp view (n=43) and cusp overlap technique (COT) (n=42).
- Primary endpoints included implantation depth and new-onset CD (new-onset left bundle branch block and permanent pacemaker implantation).
Main Results:
- The COT group demonstrated significantly higher implantation depth (noncoronary cusp: 7.4±3.0 vs 4.9±3.9; P=.005).
- New-onset CD rates were significantly lower in the COT group (31.0% vs 58.1%; P=.012).
- Lower rates of permanent pacemaker implantation were observed with COT, especially in patients without pre-existing right bundle branch block (7.7% vs 31.0%; P=.011).
Conclusions:
- The cusp overlap technique (COT) is feasible for Portico transcatheter aortic valve implantation (TAVI).
- COT facilitates a higher valve implantation depth, which is associated with reduced rates of new-onset conduction disturbances.
- COT may be a valuable strategy to improve TAVI outcomes with intra-annular valves.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Cardiac Catheterization I: Pre-Procedure Overview