Related Experiment Video
Updated: Aug 7, 2025

A Rapid, Multiplex Dual Reporter IgG and IgM SARS-CoV-2 Neutralization Assay for a Multiplexed Bead-Based Flow Analysis System
Published on: April 6, 2021
Correlation of Luminex-Based Single Antigen Based Results With Complement-Dependent Cytotoxicity Crossmatch and Flow
Suleyman Rustu Oguz1, Ayse Sinangil2, Soykan Barlas3
1Department of Medical Biology and Genetics, Demiroglu Bilim University and Group Florence Nightingale Hospital, Istanbul, Turkey; Tissue Typing Laboratory, Demiroglu Bilim University and Group Florence Nightingale Hospital, Istanbul, Turkey.
Background:
This study aimed to retrospectively investigate the correlation of mean Class I donor-specific antibody (DSA) intensity values detected in Luminex-based techniques with the results of complement-dependent cytotoxicity crossmatch (CDC-XM) and flow cytometry crossmatch (FC-XM) results.
Methods:
A total of 335 patients with kidney failure and their living donors whose CDC-XM, FC-XM, and single antigen based (SAB) tests were studied between 2018 and 2020 for transplant preparation from living donor candidates were included in the study. Patients were divided into 4 groups according to their mean fluorescence intensity (MFI) values of SAB assay.
Results:
Anti-HLA antibodies (class I and/or class II) were detected using SAB in 91.6% patients included in the study (MFI >1000). Class I DSA was positive in 34.8% of patients with anti-HLA antibodies. When CDC-XM and FC-XM results were evaluated in the 4 groups separated according to MFI values, 3 patients with DSA MFI <1000 had negative CDC-XM and T-B-FC-XM results. Of 32 patients with DSA-MFI between 1000 and 3000, 93.75% (n = 30) had T-B-FC-XM or CDC-XM-negative results, and 6.25% (n = 2) had B-FC-XM-positive results. The CDC-XM, T, and B-FC-XM were negative in all 17 patients with DSA-MFI between 3000 and 5000. Our results showed that MFI >5834 DSA values were significantly correlated with positive T-FC-XM (P < .001), and MFI >6016 values were significantly correlated with positive CDC-XM (P = .002). In addition, MFI values >5000 were associated with both CDC-XM and FC-XM in our study.
Conclusions:
The MFI values >5000 correlated with both CDC-XM and FC-XM.