Noninvasive Determination of Vortex Formation Time Using Transesophageal Echocardiography During Cardiac Surgery
Published on: November 28, 2018
Reference values for pulsed Doppler signals from the blood flow on both sides of the aortic valve
Abstract:
Pulsed Doppler signals were recorded in 215 healthy subjects, 120 males and 95 females, between 1 and 65 years of age. The measurements were performed in the left ventricular outflow tract (LVOT) and in the ascending aorta (AAO). Amplitude spectra from the Doppler signals were stored in digital form together with adjustment data for the instrument, the simultaneously registered ECG and respiration signal. The maximum velocity (Vmax), the maximum acceleration (Amax) and the width of the velocity distribution around Vmax (width) were derived from these spectra and used for the characterization of the signals. These parameters were computed without observer interaction using a computer program. Effects of age, sex, body surface area, heart rate and respiration were studied. Reference ranges were calculated. The following conclusions can be drawn: Vmax and Amax in the AAO decrease clearly with increasing age from approximately 100 to 60 cm s-1 and from 2000 to 1000 cm s-2 (medians), respectively. The variation of the width in the AAO is greater for people over 45 years. Vmax, Amax and width in the LVOT increase slightly with advancing age from approximately 60 to 80 cm s-1, 800 to 1000 cm s-2 and 12 to 15 cm s-1 (medians), respectively. These parameters of flow were either unrelated or only weakly related to other physiological variables in this study group.
Related Concept Videos
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pulse
The pulse serves as a clinical...
Aortic Regurgitation II: Clinical Features and Diagnostic Tests