Related Experiment Video
Updated: Aug 7, 2025

Introducing an Angle Adjustable Cutting Box for Analyzing Slice Shear Force in Meat
Published on: April 26, 2013
Determination of Verification Parameters for Using the Manual Sampling Device for Fresh Raw Beef Trim
Terrance M Arthur1, Ted Brown2, Tommy L Wheeler1
1U.S. Department of Agriculture, Agricultural Research Service, Roman L. Hruska U. S. Meat Animal Research Center, Clay Center, NE 68933, USA.
Beef trim sampling using the Manual Sampling Device (MSD) is adequate when covering at least half the surface for 90 seconds, or 30 seconds per side. Repeated sampling from the same bin yields similar results.
Area of Science:
- Food Science
- Microbiology
- Food Safety Engineering
Background:
- Beef processing industries employ comprehensive food safety systems to mitigate bacterial contamination risks.
- Conditional product release relies on pathogen testing, necessitating validated sample collection methods.
- Verification activities ensure the adequacy of sampling protocols in beef processing.
Purpose of the Study:
- To determine parameters for verifying adequate beef trim sampling using the Manual Sampling Device (MSD) method.
- To investigate the efficacy of repeated MSD sampling on fresh raw beef trim.
Main Methods:
- Evaluation of MSD sampling coverage area and duration on fresh raw beef trim.
- Assessment of repeated sampling from the same beef trim combo bin.
- Analysis of organism recovery and prevalence targets under varied sampling conditions.
Main Results:
- MSD sampling covering at least half the surface for a minimum of 90 seconds is adequate for fresh raw beef trim.
- MSD sampling for at least 30 seconds per side is adequate for organism recovery from raw beef trim.
- Two MSD samples from the same combo bin yield similar test results, supporting concurrent in-plant and regulatory sampling.
Conclusions:
- The study provides data supporting flexibility in accepting MSD test results when verification indicates minor deviations from protocol.
- Established MSD protocol specifications remain unchanged, but findings offer practical insights for sampling verification.
- Validated sampling parameters ensure the reliability of pathogen testing in beef processing.