Submaximal Fitness Test in Team Sports: A Systematic Review and Meta-Analysis of Exercise Heart Rate Measurement
Tzlil Shushan1, Ric Lovell2,3, Martin Buchheit4,5,6,7
1School of Health Sciences, Western Sydney University, Sydney, NSW, Australia. Tzlil21092@gmail.com.
Background:
Submaximal fitness tests (SMFT) are a pragmatic approach for evaluating athlete's physiological state, due to their time-efficient nature, low physiological burden and relative ease of administration in team sports settings. While a variety of outcome measures can be collected during SMFT, exercise heart rate (HRex) is the most popular. Understanding the measurement properties of HRex can support the interpretation of data and assist in decision making regarding athlete's current physiological state and training effects.
Objectives:
The aims of our systematic review and meta-analysis were to: (1) establish meta-analytic estimates of SMFT HRex reliability and convergent validity and (2) examine the moderating influence of athlete and protocol characteristics on the magnitude of these measurement properties.
Methods:
We conducted a systematic literature search with MEDLINE, Scopus and Web of Science databases for studies published up until January 2022 since records began. Studies were considered for inclusion when they included team sports athletes and the reliability and/or convergent validity of SMFT HRex was investigated. Reliability statistics included the group mean difference (MD), typical error of measurement (TE) and intraclass correlation coefficient (ICC) derived from test-retest(s) designs. Pearson's correlation coefficient (r) describing the relationship between SMFT HRex and a criterion measure of endurance performance was used as the statistic for convergent validity. Qualitative assessment was conducted using risk of bias assessment tool for non-randomised studies. Mixed-effects, multilevel hierarchical models combined with robust variance estimate tests were performed to obtain pooled measurement property estimates, effect heterogeneity, and meta-regression of modifying effects.
Results:
The electronic search yielded 21 reliability (29 samples) and 20 convergent validity (29 samples) studies that met the inclusion criteria. Reliability meta-analysis indicated good absolute (MD = 0.5 [95% CI 0.1 to 0.9] and TE = 1.6 [95% CI 1.4 to 1.9] % points), and high relative (ICC = 0.88 [95% CI 0.84 to 0.91]) reliability. Convergent validity meta-analysis indicated an inverse, large relationship (r = - 0.58 [95% CI - 0.62 to - 0.54]) between SMFT HRex and endurance tests performance. Meta-regression analyses suggested no meaningful influence of SMFT protocol or athlete characteristics on reliability or convergent validity estimates.
Conclusions:
Submaximal fitness test HRex is a reliable and valid proxy indicator of endurance performance in team sport athletes. Athlete and SMFT protocol characteristics do not appear to have a meaningful effect on these measurement properties. Practitioners may implement SMFT HRex for monitoring athlete's physiological state by using our applied implications to guide the interpretation of data in practice. Future research should examine the utility of SMFT HRex to track within-athlete changes in aerobic capacity, as well as any further possible effects of SMFT protocols design elements or HRex analytical methods on measurement properties. Registration Protocol registration can be found in Open Science Framework and available through https://doi.org/10.17605/OSF.IO/9C2JV .
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
07:40Impact of High-intensity Interval Exercise and Moderate-Intensity Continuous Exercise on the Cardiac Troponin T Level at an Early Stage of Training
Published on: October 10, 2019
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...