Rapid determination of free sulfur dioxide in wine and cider by capillary electrophoresis
P Layton Ashmore1, Florentino Valdez2, James F Harbertson2
1Washington State University, Department of Food Science, Richland, WA 99354.
Abstract:
A novel method for the determination of "true" free sulfur dioxide (SO2) in wine and cider was developed using capillary electrophoresis with direct ultraviolet-visible spectrophotometric detection (CE-UV/vis). Free SO2 was measured in model solutions with different SO2-binding agents present (α-ketoglutarate, pyruvate, acetaldehyde, glucose, fructose, and malvidin-3-glucoside) as well as a variety of white and red wines and ciders. The CE method was compared to three conventional methods for measuring free SO2, the Ripper method, Aeration-Oxidation (AO), and pararosaniline by discrete analyzer (DA). While some statistically significant differences (p<0.05) were found between the four methods in unpigmented model solutions and samples, the values generally agreed. In the presence of anthocyanins in model solution and red wines, free SO2 values found by CE were significantly lower than the other three methods (p<0.05). The difference in values found by Ripper and CE correlated strongly with anthocyanin content (R2 = 0.8854) and even more strongly when accounting for polymeric pigments (R2 = 0.9251). The results in red ciders differed from those in red wines, while the CE measured significantly lower free SO2 values than the other three methods, the difference in free SO2 values measured by CE and Ripper correlated more closely with anthocyanin concentration (R2 = 0.8802) than absorbance due to bleachable pigment (R2 = 0.7770). The CE method was found to be rapid (4 min/injection), sensitive (LOD=0.5 mg/L, LOQ=1.6 mg/L free SO2 in wine, 0.8 and 2.8 mg/L, respectively, in cider), robust, and repeatable (average RSD = 4.9%) and did not suffer from the issue of over-reporting free SO2 in pigmented samples often observed with currently accepted methods.
Related Concept Videos
Capillary Electrophoresis: Instrumentation
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Electrophoresis: Overview
There...