Related Experiment Video
Updated: Aug 5, 2025

Real-Time Electrocardiogram Monitoring During Treadmill Training in Mice
Published on: May 5, 2022
A Two-Step Approach to Overcoming Data Imbalance in the Development of an Electrocardiography Data Quality Assessment
Hyun Joo Kim1, S Jayakumar Venkat2, Hyoung Woo Chang2
1Department of Anesthesiology and Pain Medicine, Anesthesia and Pain Research Institute, Severance Hospital, Yonsei University College of Medicine, Seoul 03722, Republic of Korea.
Abstract:
Continuously acquired biosignals from patient monitors contain significant amounts of unusable data. During the development of a decision support system based on continuously acquired biosignals, we developed machine and deep learning algorithms to automatically classify the quality of ECG data. A total of 31,127 twenty-s ECG segments of 250 Hz were used as the training/validation dataset. Data quality was categorized into three classes: acceptable, unacceptable, and uncertain. In the training/validation dataset, 29,606 segments (95%) were in the acceptable class. Two one-step, three-class approaches and two two-step binary sequential approaches were developed using random forest (RF) and two-dimensional convolutional neural network (2D CNN) classifiers. Four approaches were tested on 9779 test samples from another hospital. On the test dataset, the two-step 2D CNN approach showed the best overall accuracy (0.85), and the one-step, three-class 2D CNN approach showed the worst overall accuracy (0.54). The most important parameter, precision in the acceptable class, was greater than 0.9 for all approaches, but recall in the acceptable class was better for the two-step approaches: one-step (0.77) vs. two-step RF (0.89) and one-step (0.51) vs. two-step 2D CNN (0.94) (p < 0.001 for both comparisons). For the ECG quality classification, where substantial data imbalance exists, the 2-step approaches showed more robust performance than the one-step approach. This algorithm can be used as a preprocessing step in artificial intelligence research using continuously acquired biosignals.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
06:07Analyzing Long-Term Electrocardiography Recordings to Detect Arrhythmias in Mice
Published on: May 23, 2021
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Imbalances in Cardiac Output
CHF can occur due to the failure of either side of the heart. Left-side failure leads to pulmonary congestion—the right side continues to send...
Dysrhythmias V: Evaluating Dysrhythmias
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Instrumentation Amplifier