Related Experiment Video
Updated: Aug 5, 2025

A Postoperative Evaluation Guideline for Computer-Assisted Reconstruction of the Mandible
Published on: January 28, 2020
Influence of different surgical techniques on primary implant stability in the posterior maxilla: a randomized
Maria-Victoria Olmedo-Gaya1, María-Nuria Romero-Olid1, Francisco M Ocaña-Peinado2
1Department of Stomatology, School of Dentistry, University of Granada, Granada, Spain.
Background And Objective:
Primary stability (PS) is remarkable for secondary stability and implant success. Surgical technique modifications seem to improve primary stability, especially in poor quality bone. The aim of this study was to compare the insertion torque (IT) and implant stability quotients (ISQ) of implants placed with underpreparation, expanders, and standard surgical instrumentation in different bone types.
Material And Methods:
This randomized controlled clinical trial enrolled 108 patients (n=108 implants) distributed in three study groups: group 1 (n=36) underpreparation technique, group 2 (n=36) expander technique, and group 3 (n=36) conventional drilling. IT was recorded with a torque indicator. ISQ was recorded with resonance frequency analysis immediately after surgery.
Results:
ISQ values were associated with the patient's bone quality and were higher in bone quality type II (76.65) and type III (73.60) and lower in bone quality type IV (67.34), with statistically significant differences (p<0.0001). Lower stability results were obtained when conventional drilling (69.31) was used compared to the use of underpreparation (74.29) or expanders (73.99) with a level of significance of p=0.008 and p=0.005, respectively.
Conclusions:
The surgical technique influences the PS when there is low-quality bone. In low-quality bones, conventional drilling obtains lower ISQ values.
Clinical Relevance:
Replace the conventional drilling technique for an alternative, underpreparation or expanders, in low-quality bone in order to achieve greater primary stability.