Calibration and thermal test results of prototype bolometer sensors for ITER fusion reactor
Sina Jahanbakhsh1, Jack Davies Hare1, Hans Meister1
1Max Planck Institute for Plasma Physics (IPP), Boltzmannstr. 2, 85748 Garching, Germany.
Abstract:
For over 10 years, several bolometer sensors with different properties have been tested in the IBOVAC facility. The aim has been to develop a bolometer sensor that can be operated in ITER and can withstand harsh operating conditions. For this purpose, important physical properties of the sensors, i.e., cooling time constant τ, normalized heat capacity κ, and normalized sensitivity sn, have been characterized in a vacuum condition and at various temperatures up to 300 °C. The calibration is achieved by ohmic heating of the sensor absorbers by applying a DC voltage and recording exponential current fall during heating. Recently, a Python program was developed to analyze the data and extract the above mentioned parameters including the uncertainties from recorded currents. In the present series of experiments, the latest prototype sensors developed for ITER are tested and evaluated. These include three different sensor types: two with Au absorbers on ZrO2 membranes (self-supporting substrate sensors) and one with Au absorbers on Si3N4 membranes supported by a Si frame (supported membrane sensors). Tests revealed that the sensor with ZrO2 substrate can only be operated up to 150 °C, while the supported membrane sensors passed the tests up to 300 °C successfully. These results will be used, together with other upcoming tests, such as irradiation testing, to select the most suitable sensors to be employed in ITER.
Related Concept Videos
Calorimetry
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Constant Pressure Calorimetry
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Gas Thermometers and the Kelvin Scale