Related Experiment Video
Updated: Aug 4, 2025

A Swin Transformer-Based Model for Thyroid Nodule Detection in Ultrasound Images
Published on: April 21, 2023
Fault Detection of Urban Wastewater Treatment Process Based on Combination of Deep Information and Transformer
Abstract:
As one of the hot issues of concerns during modern social development, the wastewater treatment process is acknowledged to be a process with complex biochemical reactions and susceptible to an external environment, featuring strong nonlinear and time correlation characteristics, which are difficult for traditional mechanism-based models to tackle. For many classical data-driven fault detection methods, a complete retraining process is necessary to monitor every new fault, and most of the current neural network-based strategies rarely achieve satisfactory monitoring accuracy or robustness either. Giving full consideration to the aforementioned problems, this article takes advantage of position encoding, residual connection, and multihead attention mechanism embedded in the Transformer structure to establish an effective and efficient wastewater treatment process fault detection model, where offline modeling and online monitoring are performed successively to achieve accurate detection of the faults. In the experimental part, the advantages of the proposed method are strongly verified through the simulation monitoring of 27 faults on the benchmark simulation model 1 (BSM1), where the false alarm rate (FAR) and miss alarm rate (MAR) of the established method are proved to be significantly lower than those of the compared state-of-the-art methods.
More Related Videos
03:31Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
Published on: December 15, 2023
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Instrument Transformers
Three-Winding Transformers
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
Power System Three-Phase Short Circuits
Differential Relays
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...