Related Experiment Video
Updated: Aug 2, 2025

09:30
Tissue Characterization after a New Disaggregation Method for Skin Micro-Grafts Generation
Published on: March 4, 2016
21.6K
Histological Comparative Analysis of Bowman Layer Grafts Procured Using 3 Different Techniques
Hyeck-Soo Son1,2,3, Loren Moon1,2,3, Jiangxia Wang1,2,3
1*Wilmer Eye Institute, Johns Hopkins Medical Institutions, Baltimore, MD.
Cornea
|April 18, 2023
Summary
Histological analysis of Bowman layer (BL) grafts revealed that no technique yielded pure BL. Peripheral scoring with forceps resulted in the thinnest grafts, though all contained residual stroma.
Area of Science:
- Ophthalmology
- Histology
- Corneal Transplantation
Background:
- Bowman layer (BL) transplantation is a key procedure in treating corneal diseases.
- Optimizing BL graft procurement is crucial for successful outcomes.
- Histological evaluation is necessary to assess graft purity and thickness.
Purpose of the Study:
- To histologically analyze Bowman layer (BL) grafts obtained using three distinct donor preparation techniques.
- To evaluate the purity and thickness of BL grafts procured for transplantation.
Main Methods:
- Bowman layer (BL) grafts were prepared from 13 human cadaver corneas using three different techniques.
- Grafts were fixed, embedded in paraffin, sectioned, and stained with Hematoxylin and eosin.
- Graft thickness was measured using image-processing software, and graft integrity was assessed.
Main Results:
- All 13 BL grafts contained residual anterior stromal tissue, indicating no technique achieved pure BL.
- BL stripping using Kelman-McPherson and Moorfield forceps resulted in the thinnest mean graft thickness (18.7 μm).
- The Melles lamellar dissector yielded the thickest grafts (279.9 μm), while blunt dissection resulted in 70.2 μm thickness.
Conclusions:
- None of the tested techniques successfully procured pure Bowman layer (BL) grafts without anterior stroma.
- Peripheral scoring and manipulation with Kelman-McPherson and Moorfield forceps produced the thinnest grafts.
- Graft integrity varied, with peripheral tears occurring in up to 100% of samples depending on the technique.