Related Experiment Video
Updated: Aug 2, 2025

A Detailed Protocol for Physiological Parameters Acquisition and Analysis in Neurosurgical Critical Patients
Published on: October 17, 2017
Which haemodynamic monitoring should we chose for critically ill patients with acute circulatory failure?
Xavier Monnet1, Christopher Lai
1AP-HP, Service de médecine intensive-réanimation, Hôpital Bicêtre, DMU CORREVE, Inserm UMR S_999, FHU SEPSIS, Groupe de recherche clinique CARMAS, Université Paris-Saclay, Le Kremlin-Bicêtre, France.
Purpose Of Review:
To discuss the suitable haemodynamic monitoring for critically ill patients with shock.
Recent Findings:
For the basic initial monitoring, recent studies emphasized the importance of clinical signs of hypoperfusion and arterial pressure. This basic monitoring is not sufficient in patients resisting to initial treatment. Echocardiography does not allow multidaily measurements and has limitations, for measuring right or left ventricular preload. For a more continuous monitoring, noninvasive and minimally invasive tools are insufficiently reliable, as recently confirmed, and informative. The most invasive techniques, transpulmonary thermodilution and the pulmonary arterial catheter are more suitable. Their effect on outcome is lacking, although recent studies showed their benefit in acute heart failure. For assessing tissue oxygenation, recent publications better defined the meaning of the indices derived from the partial pressure of carbon dioxide. The integration of all data by artificial intelligence is the subject of early research in critical care.
Summary:
For monitoring critically ill patients with shock, minimally or noninvasive systems are not reliable or informative enough. In the most severe patients, a reasonable monitoring policy can combine continuous monitoring by transpulmonary thermodilution systems or the pulmonary arterial catheter, with an intermittent assessment with ultrasound and measurement of tissue oxygenation.
Related Concept Videos
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Heart Failure V: Medical Management
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Heart Failure VI: Adjunct Therapies
Rheumatic Heart Disease IV: Nursing Management
Heart Failure VII: Nursing Interventions