Related Experiment Video
Updated: Aug 2, 2025

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Association of patent ductus arteriosus with extubation failure among preterm infants
Dhruv Gupta1, Rachel G Greenberg2, Girija Natarajan3
1Pediatrix Medical Services, Inc., El Paso, Texas, USA.
Background:
Mechanical ventilation is associated with mortality/morbidities in preterm infants. Nearly a third of these infants fail extubation, and this may increase morbidities.
Objective:
To evaluate the association of moderate to large symptomatic patent ductus arteriosus (PDA) with failure of extubation among preterm infants.
Methods:
This was a retrospective study on preterm infants (birth weight <1250 g and gestational age ≥23 weeks) born between January 2009 and December 2016, who were mechanically ventilated and extubated within the first 60 days of age.
Results:
Three hundred and sixty infants were evaluated, of these, 26% failed, and 74% succeeded in the initial extubation attempt. On adjusted analysis, symptomatic PDA was associated with an increased risk of extubation failure.
Conclusion:
The presence of symptomatic patent ductus arteriosus was associated with extubation failure. Further investigations are needed to establish whether there is a causal relationship between PDA and extubation failure and whether proactive screening for presence of PDA and treatment of the same, before extubation among these infants, improves chances of successful extubation and cardiorespiratory outcomes.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation II: ACLS Airway Management