Measurement of carbohydrates and organic acids in varieties of cheese using high-performance liquid chromatography

Mahmoud E Ahmed1, Ahmed R A Hammam1,2, Abd El-Fatah Ali3

  • 1Dairy Science Department Faculty of Agriculture Assiut University Assiut Egypt.

Related Concept Videos

Chromatographic Methods: Classification01:12

Chromatographic Methods: Classification

Chromatographic techniques are classified in three ways: the classification is based on the physical state of the stationary and mobile phases, how the mobile phase and the stationary phase contact each other, or through the chemical or physical processes that isolate the components of the sample. Typically, the mobile phase is either a liquid or gas, while the stationary phase is either a solid or a liquid layer applied to a solid surface.
Chromatographic techniques are typically named by...
2.4K
High-Performance Liquid Chromatography: Types of Detectors01:15

High-Performance Liquid Chromatography: Types of Detectors

The role of the detectors in High-Performance Liquid Chromatography (HPLC) is to analyze the solutes as they exit from the chromatographic column. The detector recognizes the solute's property and generates corresponding electrical signals, which are converted into a readable graph of the detector's response versus elution time called a chromatogram at the computer. There are several types of HPLC detectors, each with its own advantages and limitations, depending on the analyte...
644
NMR and Mass Spectroscopy of Carboxylic Acids01:30

NMR and Mass Spectroscopy of Carboxylic Acids

In ¹H NMR spectroscopy, acidic protons (–COOH) of carboxylic acids are highly deshielded and absorb far downfield, at around 9–12 ppm. The chemical shift value depends on the concentration and solvent used.
While α protons of carboxylic acids absorb at 2–2.5 ppm, β protons absorb further upfield.
Carboxylic acids are easily identified by dissolving them in deuterium oxide, which results in a rapid exchange of the acidic protons with deuterium. This leads to the...
4.1K
Spectroscopy of Carboxylic Acid Derivatives01:26

Spectroscopy of Carboxylic Acid Derivatives

Infrared spectroscopy is primarily used to determine the types of bonds and functional groups. In carboxylic acid derivatives, a typical carbonyl bond absorption is observed around 1650–1850 cm−1. For esters, the absorption is recorded at around 1740 cm−1, while acid halides show the absorption at about 1800 cm−1. Another acid derivative, the acid anhydrides, exhibit two carbonyl absorption around 1760 cm−1 and 1820 cm−1, arising from the symmetrical and...
2.5K
High-Performance Liquid Chromatography: Instrumentation00:57

High-Performance Liquid Chromatography: Instrumentation

High-performance liquid chromatography, or HPLC, is an analytical technique that separates liquid samples under high pressures. An HPLC instrument consists of glass bottles for storing solvents called mobile phase reservoirs. HPLC-grade solvents are used to maintain high purity, and the dissolved gases are removed using a degasser, such as a vacuum pumping system or sparging with helium. The solvents are then pumped into the analytical column using a screw-driven syringe or reciprocating pumps.
1.9K
IR and UV–Vis Spectroscopy of Carboxylic Acids01:28

IR and UV–Vis Spectroscopy of Carboxylic Acids

In IR spectroscopy of carboxylic acids, the C=O bond shows a characteristic band between 1710 and 1760 cm⁻¹, and the O–H bond exhibits a broad band between 2500 and 3300 cm⁻¹.
However, the stretching absorptions for the C=O bond vary depending on the structure of carboxylic acids. The C=O bond of the free carboxylic acids shows a higher stretching frequency, 1760 cm−1, while H-bonded carboxylic acids (dimers) exhibit stretching absorptions at a lower frequency,...
4.4K