Related Experiment Video
Updated: Jul 30, 2025

Author Spotlight: Expanding Interventional Pulmonology Research with Robotic-Assisted Bronchoscopy
Published on: July 19, 2024
Technical note: Semiautomated targeted postmortem computed tomography angiography of the pulmonary arteries using a
Sabine Franckenberg1, Till Sieberth2, Wolfgang Ptacek3
1Department of Forensic Medicine and Imaging, Institute of Forensic Medicine, University of Zurich, Switzerland; Department of Diagnostic and Interventional Radiology, University Hospital Zurich, Switzerland.
Introduction:
To better depict vascular lesions on postmortem computed tomography (PMCT), whole-body postmortem computed tomography angiography (PMCTA) can be used in forensic diagnostics. Targeted angiography, in which only a specific vessel is filled with contrast agent, might help in cases of traumatic changes that render whole-body PMCTA impossible. Moreover, in targeted PMCTA, the contrast agent does not affect the haptics of any other organs. In this article, we describe automated, CT-guided targeted angiography of the pulmonary artery (PA) using the Virtobot system.
Material And Methods:
Our study group consisted of 8 deceased persons (3 males, 5 females). We first performed an unenhanced CT scan and used the data obtained to plan the needle trajectories with the Virtobot planning software. Then, the needle was fully automatically placed by the Virtobot system. Subsequently, 50 ml of contrast agent was injected manually, and the CT scan was repeated (targeted PMCTA).
Results And Discussion:
We tested a new method for performing semiautomated targeted postmortem angiography of the PAs using a robotic needle placement system (Virtobot). In 6 out of our 8 cases, the injection of contrast agent in the PA was successful. In five of the six successful cases, there was reflux of contrast agent to some extent, but the reflux did not affect the readout. In general, the procedure was easy to plan based on a PMCT data set, and the pulmonary trunk was easy to reach with a robotic needle placement system.
More Related Videos
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
09:57Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...