Related Experiment Video
Updated: Jul 29, 2025

Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental Study on the Performance of Steel-Fiber-Reinforced Concrete for Remote-Pumping Construction
Minglei Zhao1, Changyong Li2, Jie Li1
1School of Engineering, RMIT University, Melbourne 3001, Australia.
Abstract:
Remote-pumped concrete for infrastructure construction is a key innovation of the mechanized and intelligent construction technology. This has brought steel-fiber-reinforced concrete (SFRC) into undergoing various developments, from conventional flowability to high pumpability with low-carbon features. In this regard, an experimental study on the mixing proportion design and the pumpability and mechanical properties of SFRC was conducted for remote pumping. Using the absolute volume method based on the steel-fiber-aggregate skeleton packing test, the water dosage and the sand ratio were adjusted with an experimental study on reference concrete with the premise of varying the volume fraction of steel fiber from 0.4% to 1.2%. The test results of the pumpability of fresh SFRC indicated that the pressure bleeding rate and the static segregation rate were not the controlling indices due to the fact that they were far below the limits of the specifications, and the slump flowability fitted for remote-pumping construction was verified by a lab pumping test. Although the rheological properties of the SFRC charactered by the yield stress and the plastic viscosity increased with the volume fraction of steel fiber, those of mortar used as a lubricating layer during the pumping was almost constant. The cubic compressive strength of the SFRC had a tendency to increase with the volume fraction of steel fiber. The reinforcement effect of steel fiber on the splitting tensile strength of the SFRC was similar to the specifications, while its effect on the flexural strength was higher than the specifications due to the special feature of steel fibers distributed along the longitudinal direction of the beam specimens. The SFRC had excellent impact resistance with an increased volume fraction of steel fiber and presented acceptable water impermeability.
Related Concept Videos
Fiber Reinforced Concrete
Pumped Concrete
For direct-acting pumps, the concrete enters the pump via the inlet valve under the action of gravity and suction created by the movement of the piston. This concrete is then forced into the pipeline and out through the outlet valve by the forward movement...
Reinforcements in Concrete
Non-destructive Tests for Concrete Strength
Fatigue Strength of Concrete
Impact Strength of Concrete