Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
Sensitivity comparison of gas chromatography-mass spectrometry with Cold EI and standard EI
Aviv Amirav1,2, Alex Yakovchuk1
1School of Chemistry, Tel Aviv University, Tel Aviv, Israel.
Abstract:
Gas chromatography-mass spectrometry (GC-MS) with Cold EI is based on interfacing GC and MS with supersonic molecular beams (SMBs) along with electron ionization of vibrationally cold sample compounds in SMB in a fly-through ion source (hence the name Cold EI). Cold EI improves all the central performance aspects of GC-MS, and in this paper, we focus on its improvement of signal-to-noise ratio (S/N) and limits of detection (LODs). We found that the harder the compound for analysis with standard EI, the greater the Cold EI gain in S/N and LOD. The lower LOD and higher S/N of Cold EI emerge from a few reasons: (a) similar ionization yield as standard EI, (b) enhanced abundance of molecular ions, (c) elimination of vacuum background noise, (d) elimination of ion source-related peak tailing and degradation, (e) ability to lower the elution temperatures via the use of high column flow rates, and (f) greater range of thermally labile and low-volatility compounds that can be analyzed. We demonstrate the superior S/N and lower LOD of Cold EI versus standard EI in a range of compounds, from the simple-to-analyze octafluoronaphthalene all the way to reserpine and an organo-metallic compound that cannot be analyzed by standard EI. These compounds include methyl stearate, cholesterol, n-C32 H66 , large polycyclic aromatic hydrocarbons, dioctyl phthalates, diundecyl phthalate, pentachlorophenol, benzidine, lambda-cyhalothrin, and methidathion. The significantly lower Cold EI LODs that can be over 1000 times better than in standard EI further result in far superior response linearity and greater measurement dynamic range.
More Related Videos
06:51Quantitative Analysis by Thermogravimetry-Mass Spectrum Analysis for Reactions with Evolved Gases
Published on: October 29, 2018
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Chemical Ionization (CI) Mass Spectrometry
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...