Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Development and Application of a Novel Multiloop Splitter-Based Non-cryogenic Artificial Trapping Modulation System
Nuttanee Tungkijanansin1, Yada Nolvachai2,3, Puttaruksa Varanusupakul1
1Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.
Abstract:
A multiloop splitter-based non-cryogenic artificial trapping (M-SNAT) modulation technique was established, which applied the first (1D) nonpolar and the second (2D) polar columns, deactivated fused silica (DFS) columns, a microfluidic Deans switch (DS), and splitters located between the 1D column outlet and the DS. The splitters were connected into multiple loops with a progressively doubled perimeter of the next loop. This enabled a duplex splitting mechanism within each loop consisting of splitting of analyte pulses, the pulse delay, and their combination which led to equally split peaks of the same analytes with the number of split peaks (nsplit) equal to 2m (m = number of loops). This system resulted in local profiles of artificially split-and-trapped analytes prior to their selective transfers onto the 2D column by means of periodic multiple heart-cuts (H/C). The developed SNAT approach can be successful, providing that the ratio of modulation period to sampling time (PM/tsamp) is equal to nsplit. The approach with nsplit = 16 was further developed into a single device platform and applied for the modulation of a wide range of compounds in waste tire pyrolysis samples with the RSD of ≤0.01 and <10% for the one-dimensional modulated peak times and peak areas, respectively (n = 50). The method enabled an artificial modulation mechanism without cryogen consumption and enhanced the 2D peak capacity (2nc) and 2D separation by use of a longer 2D column.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...