Related Experiment Video
Updated: Jul 27, 2025

Multiplexing Focused Ultrasound Stimulation with Fluorescence Microscopy
Published on: January 7, 2019
Focusing Reflected Ultrasound Using Boundary Element Model for Mid-Air Tactile Presentation
This study introduces a new method for ultrasound focusing using curved reflectors for mid-air tactile feedback. The technique enables precise, real-time tactile sensations without prior calibration, enhancing focus intensity and enabling new haptic applications.
Area of Science:
- Acoustics
- Haptics
- Wave physics
Background:
- Mid-air tactile presentation using ultrasound offers advantages like multi-directional sensation and reduced transducer array conflicts.
- Previous methods for ultrasound focusing with curved reflectors often required extensive prior measurements and lacked real-time adaptability.
Purpose of the Study:
- To propose a novel method for focusing reflected ultrasound using curved surfaces for enhanced mid-air tactile feedback.
- To enable real-time focusing on arbitrary locations without pre-measurement of transducer responses.
- To improve focus intensity by integrating target object characteristics into the modeling.
Main Methods:
- Solving the boundary integral equation for the sound field on an element-divided reflector.
- Formulating the relationship between transducer input and reflected sound field for real-time control.
- Incorporating the tactile presentation's target object into a boundary element model to enhance focus intensity.
Main Results:
- Demonstrated successful ultrasound focusing from a hemispherical dome using numerical simulations and experimental measurements.
- Validated the proposed method's ability to achieve focused ultrasound at desired locations.
- Identified regions where sufficient focus intensity could be generated through numerical analysis.
Conclusions:
- The proposed boundary integral equation method effectively achieves ultrasound focusing with curved reflectors for mid-air tactile presentation.
- This approach allows for real-time, adaptable tactile feedback without the need for individual transducer calibration.
- The method shows potential for creating more immersive and precise haptic experiences.
More Related Videos
08:19Controllable Nucleation of Cavitation from Plasmonic Gold Nanoparticles for Enhancing High Intensity Focused Ultrasound Applications
Published on: October 5, 2018
08:08Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019