Assessment of Midline Lingual Point-Pressure Somatosensation Using Von Frey Hair Monofilaments
Published on: February 21, 2020
Real-Time Continuous Monitoring of Oral Soft Tissue Pressure with a Wireless Mouthguard Device for Assessing Tongue
Hidekazu Matsumoto1, Keisuke Tomoto2, Gentaro Kawase2
1Department of Maxillofacial Orthognathics, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University, Tokyo 113-8549, Japan.
Abstract:
In orthodontics, understanding the pressure of oral soft tissues on teeth is important to elucidate the cause and establish treatment methods. We developed a small wireless mouthguard (MG)-type device that continuously and unrestrainedly measures pressure, which had previously been unachieved, and evaluated its feasibility in human subjects. First, the optimal device components were considered. Next, the devices were compared with wired-type systems. Subsequently, the devices were fabricated for human testing to measure tongue pressure during swallowing. The highest sensitivity (51-510 g/cm2) with minimum error (CV < 5%) was obtained using an MG device with polyethylene terephthalate glycol and ethylene vinyl acetate for the lower and upper layers, respectively, and with a 4 mm PMMA plate. A high correlation coefficient (0.969) was observed between the wired and wireless devices. In the measurements of tongue pressure on teeth during swallowing, 132.14 ± 21.37 g/cm2 for normal and 201.17 ± 38.12 g/cm2 for simulated tongue thrust were found to be significantly different using a t-test (n = 50, p = 6.2 × 10-19), which is consistent with the results of a previous study. This device can contribute to assessing tongue thrusting habits. In the future, this device is expected to measure changes in the pressure exerted on teeth during daily life.
Related Concept Videos
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Suctioning the Oropharyngeal Airway
After assembling the equipment, the nurse should practice hand hygiene and don appropriate PPE according to infection control guidelines to avoid the...