Related Experiment Video
Updated: Jul 26, 2025

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Impact of an Automated Closed-Loop Communication and Tracking Tool on the Rate of Recommendations for Additional
Ariadne K DeSimone1, Neena Kapoor2, Ronilda Lacson3
1Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts.
Objective:
Assess the effects of feedback reports and implementing a closed-loop communication system on rates of recommendations for additional imaging (RAIs) in thoracic radiology reports.
Methods:
In this retrospective, institutional review board-approved study at an academic quaternary care hospital, we analyzed 176,498 thoracic radiology reports during a pre-intervention (baseline) period from April 1, 2018, to November 30, 2018; a feedback report only period from December 1, 2018, to September 30, 2019; and a closed-loop communication system plus feedback report (IT intervention) period from October 1, 2019, to December 31, 2020, promoting explicit documentation of rationale, time frame, and imaging modality for RAI, defined as complete RAI. A previously validated natural language processing tool was used to classify reports with an RAI. Primary outcome of rate of RAI was compared using a control chart. Multivariable logistic regression determined factors associated with likelihood of RAI. We also estimated the completeness of RAI in reports comparing IT intervention to baseline using χ2 statistic.
Results:
The natural language processing tool classified 3.2% (5,682 of 176,498) reports as having an RAI; 3.5% (1,783 of 51,323) during the pre-intervention period, 3.8% (2,147 of 56,722) during the feedback report only period (odds ratio: 1.1, P = .03), and 2.6% (1,752 of 68,453) during the IT intervention period (odds ratio: 0.60, P < .001). In subanalysis, the proportion of incomplete RAI decreased from 84.0% (79 of 94) during the pre-intervention period to 48.5% (47 of 97) during the IT intervention period (P < .001).
Discussion:
Feedback reports alone increased RAI rates, and an IT intervention promoting documentation of complete RAI in addition to feedback reports led to significant reductions in RAI rate, incomplete RAI, and improved overall completeness of the radiology recommendations.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
X-ray Imaging

