Feasibility of Speech Testing Using Wireless Connection in Single-Sided Cochlear Implant Users.
Seong Hoon Bae1, Youngrak Jung2, Ji Hye Hur2
1Department of Otorhinolaryngology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Korea.
Wireless speech testing is a reliable method for evaluating cochlear implant (CI) performance in single-sided deafness (SSD) patients. This approach is more effective than traditional methods, particularly the "plugged and muffed" technique.
Area of Science:
- Audiology
- Otorhinolaryngology
- Biomedical Engineering
Background:
- Current speech tests for cochlear implant (CI) patients with bilateral deafness (BiD) are unsuitable for those with single-sided deafness (SSD) due to the need to exclude normal hearing.
- Evaluating the CI ear in SSD patients requires methods that effectively isolate its performance.
Purpose of the Study:
- To assess the feasibility of using a wireless connection for speech intelligibility testing in the CI ear of SSD patients.
- To compare wireless testing with conventional methods for both BiD and SSD populations.
Main Methods:
- Patients with BiD and SSD underwent word recognition scores (WRS) and speech intelligibility tests.
- Testing utilized an iPad-based wireless connection and conventional approaches.
- For SSD patients, masking noise (WRS) and a "plugged and muffed" method (speech intelligibility) were employed to exclude the non-CI ear's contribution.
Main Results:
- Wireless and conventional methods yielded similar WRS and speech intelligibility results in BiD patients.
- For SSD patients, WRS with masking noise in the normal ear correlated well with wireless testing results.
- The "plugged and muffed" method resulted in under-masking in 3 out of 11 SSD patients.
Conclusions:
- Wireless speech intelligibility testing offers a convenient and dependable way to assess CI performance in SSD patients.
- The "plugged and muffed" method is not recommended for evaluating CI performance in SSD due to potential under-masking issues.