HPC Data Center Participation in Demand Response: an Adaptive Policy with QoS Assurance
Yijia Zhang1, Daniel C Wilson1, Ioannis Ch Paschalidis1
1Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215.
Summary
High-performance computing (HPC) data centers can now join electricity grid regulation services. Our new policy ensures job quality of service (QoS) while reducing costs by up to 56%.
Area of Science:
- Computer Science
- Electrical Engineering
- Operations Research
Background:
- Demand response programs incentivize grid stability by adjusting consumer power usage.
- Regulation service requires rapid power adjustments, aligning with HPC data center flexibility.
- Existing research on data centers in regulation services overlooks Quality-of-Service (QoS).
Purpose of the Study:
- To develop a data center policy for participating in regulation services while guaranteeing job QoS.
- To address the gap in prior work concerning QoS provisioning in data center demand response.
Main Methods:
- Proposed an Adaptive policy integrating job scheduling and server power capping for power regulation.
- Utilized queueing theory to ensure job QoS within the scheduling strategy.
- Conducted experiments on a real HPC cluster to validate the policy.
Main Results:
- The Adaptive policy reduced electricity costs by 25-56% compared to baseline policies.
- Guaranteed job QoS was maintained throughout the regulation service participation.
- Baseline policies failed to meet QoS constraints in a significant portion (9 out of 14) of tested workloads.
Conclusions:
- The proposed Adaptive policy effectively enables HPC data centers to participate in regulation services.
- The policy successfully balances grid stabilization objectives with essential job QoS requirements.
- This approach offers a practical solution for cost reduction and reliable operation in data centers engaged in demand response.
Related Concept Videos
Maximum Power Flow and Line Loadability
140
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
140
Power System Distribution
273
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
273
Power Factor Correction
214
The power transmission to a factory involves the transfer of apparent power, a combination of active and reactive power. The power factor measures how effectively electrical power is converted into useful work output. The ratio of the real power (KW) that does the work to the apparent power (KVA) supplied to the circuit.
214
Health Information Technology and Healthcare Information System
877
Health Information Technology (HIT)
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
Health Information Technology, commonly called HIT, integrates advanced information systems and technology in healthcare settings. Its primary functions include:
877
Distributed Loads: Problem Solving
680
Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
680
Distributed Loads
559
Distributed loads are a common type of load that engineers and scientists encounter in various practical situations. Distributed loads often refer to a type of load spread over a surface or a structure and can be modeled as continuous force per unit area.
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
For example, consider a bookshelf filled with books stacked vertically adjacent to each other. The weight of the books is evenly distributed over the length of the shelf. As a result, the pressure at different locations on the surface of the...
559