Effect of Moisture Condition of Structural Lightweight Concretes on Specified Values of Static and Dynamic Modulus of
Lucyna Domagała1, Kinga Sieja1
1Faculty of Civil Engineering, Cracow University of Technology, 31-155 Kraków, Poland.
Abstract:
The dynamic modulus of elasticity (E), specified by ultrasonic pulse velocity measurements, is often used, especially for concrete built into construction, to estimate the static modulus of elasticity (E). However, the most commonly used Equations for such estimations do not take into account the influence of concrete moisture. The aim of this paper was to establish this influence for two series of structural lightweight aggregate concrete (LWAC) varying in their strength (40.2 and 54.3 MPa) and density (1690 and 1780 kg/m3). The effect of LWAC moisture content turned out to be much more pronounced in the case of dynamic modulus measurements than for static ones. The achieved results indicate that the moisture content of the concrete should be taken into consideration in modulus measurements as well as in Equations estimating E on the basis of E specified by the ultrasonic pulse velocity method. The static modulus of LWACs was lower on average by 11 and 24% in relation to dynamic modulus, respectively when measured in air-dried and water-saturated conditions. The influence of LWAC moisture content on the relationship between specified static and dynamic moduli was not affected by the type of tested lightweight concrete.
More Related Videos
11:38Environmentally-controlled Microtensile Testing of Mechanically-adaptive Polymer Nanocomposites for ex vivo Characterization
Published on: August 20, 2013
05:26Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Related Concept Videos
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Elasticity in Concrete
Moisture Content and Bulking of Aggregate
When aggregates are exposed to rain or sit in stockpiles, they absorb moisture, which must be...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Fatigue Strength of Concrete
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...