Related Experiment Video
Updated: Jul 25, 2025

Simulation of Human-induced Vibrations Based on the Characterized In-field Pedestrian Behavior
Published on: April 13, 2016
Research on the impact of irregular structure group construction on rail transit bridge piers and its response to
Yan Wang1, Zheng Chen2, Yi Qi3
1School of Civil Engineering, Qingdao University of Technology, Qingdao, 266520, Shandong, China. wangyantumu@qut.edu.cn.
Abstract:
The possibility of deformation and collision in existing railway bridge foundation structures due to the construction of a group of large irregular structures in close proximity and their potential for overturning under strong wind loads is posed as a potential threat. The impact of the construction of large irregular sculptures on bridge piers and their response under strong wind loads is primarily investigated in this study. A modeling method based on real 3D spatial information of the bridge structure, geological structure, and sculpture structure is proposed to accurately reflect their spatial relationships. Finite difference method is employed to analyze the impact of sculpture structure construction on pier deformations and ground settlement. The bridge structure exhibits small overall deformation, with maximum horizontal and vertical displacements of the piers located at the edge of the bent cap on the side of the critical neighboring bridge pier J24 adjacent to the sculpture. A fluid-solid coupling model of the interaction between the sculpture structure and wind loads with two different direction is established using computational fluid dynamics, and theoretical analysis and numerical calculations are conducted on the sculpture's anti-overturning performance. The internal force indicators such as displacement, stress, and moment of the sculpture structure in the flow field under two working conditions are studied, and comparative analysis of typical structures is conducted. It is shown that sculpture A and B have different unfavorable wind directions and specific internal force distributions and response patterns due to the influence of size effects. Under both working conditions, the sculpture structure remains safe and stable.
Related Concept Videos
Resultant of a General Distributed Loading
Examples such as load distribution due to wind and load distribution on a bridge illustrate how this concept is used to analyze and design safe, reliable structures under variable loading conditions. Most structures, such as residential buildings, bridges, and towers, are...
Indeterminate Structure
Applications of Stress
The...
Elastic Curve from the Load Distribution
For all beams, the analysis of the beam's reaction to distributed loads begins by understanding the relationship between a beam's load and the resulting shear forces and bending moments.
Internal Loadings in Structural Members: Problem Solving
To illustrate this, let's consider a beam OC of 5 kN, inclined at an angle of 53.13° with the horizontal and supported at both ends. Determine the internal...
Unsymmetric Loading of Thin-Walled Members
The concept of the shear center is crucial in countering the...

