Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Accurate prediction of isothermal gas chromatographic Kováts retention indices
Afia Anjum1, Jaanus Liigand2, Ralph Milford2
1Department of Computing Science, University of Alberta, Edmonton, AB T6G 2E9, Canada.
Abstract:
We describe a freely available web server called Retention Index Predictor (RIpred) (https://ripred.ca) that rapidly and accurately predicts Gas Chromatographic Kováts Retention Indices (RI) using SMILES strings as chemical structure input. RIpred performs RI prediction for three different stationary phases (semi-standard non-polar (SSNP), standard non-polar (SNP), and standard polar (SP)) for both derivatized (trimethylsilyl (TMS) and tert‑butyldimethylsilyl (TBDMS) derivatized) and underivatized (base compound) forms of GC-amenable structures. RIpred was developed to address the need for freely available, fast, highly accurate RI predictions for a wide range of derivatized and underivatized chemicals for all common GC stationary phases. RIpred was trained using a Graph Neural Network (GNN) that used compound structures, their extracted features (mostly atom-level features) and the GC-RI data from the National Institute of Standards and Technology databases (NIST 17 and NIST 20). We curated this NIST 17 and NIST 20 GC-RI data, which is available for all three stationary phases, to create appropriate inputs (molecular graphs in this case) needed to enhance our model performance. The performance of different RIpred predictive models was evaluated using 10-fold cross validation (CV). The best performing RIpred models were identified and when tested on hold-out test sets from all stationary phases, achieved a Mean Absolute Error (MAE) of <73 RI units (SSNP: 16.5-29.5, SNP: 38.5-45.9, SP: 46.52-72.53). The Mean Absolute Percentage Error (MAPE) of these models were typically within 3% (SSNP: 0.78-1.62%, SNP: 1.87-2.88%, SP: 2.34-4.05%). When compared to the best performing model by Qu et al., 2021, RIpred performed similarly (MAE of 16.57 RI units [RIpred] vs. 16.84 RI units [Qu et al., 2021 predictor] for derivatized compounds). RIpred also includes ∼5 million predicted RI values for all GC-amenable compounds (∼57,000) in the Human Metabolome Database HMDB 5.0 (Wishart et al., 2022).
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...