Muhammad Asif1, Imran Khattak2, Asim Qureshi3
1Operative Dentistry, Rehamat Memorial Hospital, Abbottabad.
Journal of Ayub Medical College, Abbottabad : JAMC
|July 9, 2023
Summary
For dental restorations, sectional matrix bands provide tighter contacts than circumferential bands. This study compared Palodent Plus sectional and Tofflemire circumferential systems for Class II composite restorations.
Area of Science:
- Restorative Dentistry
- Dental Materials Science
Background:
- Achieving tight proximal contacts in Class II composite restorations is challenging.
- Circumferential and sectional matrix bands are commonly used for proximal restorations.
Purpose of the Study:
- To compare the contact tightness achieved with sectional (Palodent Plus) and circumferential (Tofflemire) matrix band systems.
- To evaluate the effectiveness of different matrix systems in composite restorations.
Main Methods:
- A quasi-experimental study involving 30 patients (60 cavities).
- Both Tofflemire and Palodent Plus systems were used in each patient for Class II composite restorations.
- Contact tightness was assessed using Fédération Dentaire Internationale criteria.
Main Results:
- The Palodent Plus system demonstrated superior contact tightness compared to the Tofflemire system.
- Statistically significant differences (p=.037) were found in contact tightness between the two systems.
- Palodent Plus achieved higher scores for tight contacts (55% score 1, 28.3% score 2) versus Tofflemire (46.7% score 4, 31.7% score 5).
Conclusions:
- Sectional matrix band systems are statistically superior to circumferential systems for achieving tight contacts in Class II composite restorations.
- The Palodent Plus system offers better outcomes for proximal contact tightness.