Visual impression and texture analysis of advanced modeled iterative reconstruction (ADMIRE): improved assessment of
Babak Alikhani1,2, Hans-Jürgen Raatschen2, Frank Wacker2
1Center for Radiology and Nuclear Medicine, DIAKOVERE Hospital gGmbH, Hannover, Germany.
Abstract:
To evaluate the image quality (IQ) of advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) applying image texture and image visual impression as a supplement to physical parameters such as noise level and spatial resolution. An ACR-phantom with four modules was examined at different radiation dose levels. To characterise the image texture, two Haralick texture parameters, contrast and entropy, were assessed at different dose levels and reconstruction algorithms. The visual impression of images and the low-contrast detectability were evaluated by the structural similarity index (SSIM). The spatial resolution was determined by the modulation transfer functions and the line spread function. The Haralick texture parameters, contrast and entropy, decreased with increasing ADMIRE levels. ADMIRE III, IV and V offered a comparable contrast and entropy to those calculated by filtered back projection (FBP) with a radiation dose reduction up to 50%. SSIM (low-contrast detectability) improved with increasing ADMIRE levels. SSIM calculated by ADMIRE IV and V revealed comparable IQ to FBP with a decreased CTDIvolup to 50%. Spatial resolution was retained up to 90% dose reduction. Compared to FBP at the same dose level, the image noise decreased up to 61% with higher ADMIRE levels (σFBP= 17.3 HU andσADMIREV= 10.6 HU at 6.65 mGy). Taking texture analysis and visual perception into account, a more realistic assessment of the dose reduction potential of ADMIRE can be achieved than quality metrics based alone on physical measurements.
More Related Videos
09:00Visualization of Failure and the Associated Grain-Scale Mechanical Behavior of Granular Soils under Shear using Synchrotron X-Ray Micro-Tomography
Published on: September 29, 2019
12:39DUCT: Double Resin Casting followed by Micro-Computed Tomography for 3D Liver Analysis
Published on: September 28, 2021
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan: