First Generation of a Modular Interoperable Closed-Loop System for Automated Insulin Delivery in Patients With Type 1
Pierre-Yves Benhamou1,2, Alice Adenis3, Sandrine Lablanche1
1Department of Endocrinology, Grenoble University Hospital, Grenoble Alpes University, INSERM U1055, Laboratory of Fundamental and Applied Bioenergetics, Grenoble, France.
The Diabeloop Generation 1 closed-loop system significantly improves time in range and reduces hypoglycemia for type 1 diabetes patients. This efficient, safe, and interoperable system shows consistent results across diverse populations and pump types.
Area of Science:
- Endocrinology
- Medical Devices
- Diabetes Technology
Background:
- Diabeloop Generation 1 (DBLG1) is a leading commercial closed-loop system for type 1 diabetes management.
- It is one of five such systems available globally as of 2023.
Purpose of the Study:
- To provide a comprehensive overview of data concerning DBLG1 system outcomes and patient populations.
- To emphasize the system's interoperability with different insulin pumps.
Main Methods:
- Analysis of data from three randomized control trials and five real-life surveys.
- Data collection spanned from March 2017 to April 2022, involving 6859 adult patients.
- Evaluation of system performance with three different insulin pump systems: Vicentra Kaleido, Sooil Dana-I, and Roche Insight.
Main Results:
- Significant improvement in Time in Range (TIR) of 70-180 mg/dL, increasing by 12.2-17.3 percentage points (from 47.4% to 56.6%).
- Average reduction in time spent in hypoglycemia by 48% (range: 26%-70%), reaching 1.3% in the largest cohort.
- A 59% reduction in Time Below Range (TBR) for patients with baseline hypoglycemia (≥5%).
Conclusions:
- The DBLG1 closed-loop system demonstrates efficiency, safety, and interoperability across various European countries and pump types.
- Consistent improvements in TIR and reductions in hypoglycemia confirm the system's effectiveness.
- The system's ability to integrate with multiple pump settings highlights its interoperability.
More Related Videos
07:55A Multi-Parametric Islet Perifusion System within a Microfluidic Perifusion Device
Published on: January 26, 2010
09:08Three-dimensional Printing of Thermoplastic Materials to Create Automated Syringe Pumps with Feedback Control for Microfluidic Applications
Published on: August 30, 2018
Related Concept Videos
Insulin Formulations: Types and Delivery
Short-acting insulins are divided into...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Diabetes Mellitus: Overview and Type I Subtype
Type 1 diabetes is an autoimmune disease in which the immune system mistakenly attacks and destroys the insulin-producing beta cells in the pancreas. As a result, the body is unable to produce sufficient insulin, and individuals with...
Insulin: Biosynthesis, Chemistry, and Preparation
Damage or functional impairment of β-cells inhibits insulin production, leading to diabetes. Diabetes treatment...
Diabetes Mellitus: Type 2 and Gestational
Diabetes: Management and Pharmacotherapy
Insulin remains the cornerstone of treatment for most patients with type 1 and many...