Abstract:
This article presents an electrocardiogram (ECG) delineation and arrhythmia heartbeat detection system using a novel second-order level-crossing sampling analog to digital converter (ADC) for real-time data compression and feature extraction. The proposed system consists of the front-end integrated circuit of the data converter, the delineation algorithm, and the arrhythmia detection algorithm. Compared with conventional level-sampling ADCs, the proposed circuit updates tracking thresholds using linear extrapolation, which forms a second-order level-crossing sampling ADC that has sloped sampling levels. The computing is done digitally and is implemented by modifying the digital control logic of a conventional Successive-approximation-register (SAR) ADC. The system separates the sampling and quantization processes and only selects the turning points in the input waveform for quantization. The output of the proposed data converter consists of both the digital value of the selected sampling points and the timestamp between the selected sampling points. The main advantages are data savings for the data converter and the following digital signal processing or communication circuits, which are ideal for low-power sensors. The test chip was fabricated using a 180 nm CMOS process. When sensing sparse signals such as ECG signals the proposed ADC achieves a compression factor of 8.33. The delineation algorithm uses a triangle filter method to locate the fiducial points and measures the intervals, slopes, and morphology of the QRS complex and the P/T waves. Those extracted features are then used in the arrhythmia heartbeat detection algorithm to identify Premature Ventricular Contraction (PVC). The overall performance of the system is evaluated using the MIT-BIH database and the QT database, which is also compared with the recently reported systems. The accuracy, sensitivity, specificity, PPV, and F1 score are 97.3%, 89.6%, 97.8%, 73.3%, and 0.81 for detecting PVC.
More Related Videos
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
09:36Dual-Dye Optical Mapping of Hearts from RyR2R2474S Knock-In Mice of Catecholaminergic Polymorphic Ventricular Tachycardia
Published on: December 22, 2023
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...