Stats on the desats: alarm fatigue and the implications for patient safety
Hannah R Anderson1, Alex C Borgen1, Rebecca Christnacht1
1Physician Assistant Program, Mayo Clinic, Rochester, Minnesota, USA.
Background:
Physiological monitoring systems, like Masimo, used during inpatient hospitalisation, offer a non-invasive approach to capture critical vital signs data. These systems trigger alarms when measurements deviate from preset parameters. However, often non-urgent or potentially false alarms contribute to 'alarm fatigue,' a form of sensory overload that can have adverse effects on both patients and healthcare staff. The Joint Commission, in 2021, announced a target to mitigate alarm fatigue-related fatalities through improved alarm management. Yet, no established guidelines are presently available. This study aims to address alarm fatigue at the Mayo Clinic to safeguard patient safety, curb staff burnout and improve the sensitivity of oxygen saturation monitoring to promptly detect emergencies.
Methods:
A quality improvement project was conducted to combat minimise the false alarm burden, with data collected 2 months prior to intervention commencement. The project's goal was to decrease the total alarm value by 20% from 55%-85% to 35%-75% within 2 months, leveraging quality improvement methodologies.
Interventions:
February to April 2021, we implemented a two-pronged intervention: (1) instituting a protocol to evaluate patients' continuous monitoring needs and discontinuing it when appropriate, and (2) introducing educational signage for patients and Mayo Clinic staff on monitoring best practices.
Results:
Baseline averages of red alarms (158.6), manual snoozes (37.8) and self-resolves (120.7); the first postintervention phase showed reductions in red alarms (125.5), manual snoozes (17.8) and self-resolves (107.8). Second postintervention phase recorded 138 red alarms, 13 manual snoozes and 125 self-resolves. Baseline comparison demonstrated an average of 16.92% reduction of alarms among both interventions (p value: 0.25).
Conclusion:
Simple interventions like education and communication techniques proved instrumental in lessening the alarm burden for patients and staff. The findings underscore the practical use and efficacy of these methods in any healthcare setting, thus contributing to mitigating the prevalent issue of alarm fatigue.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Insufficient Sleep and Sleep Deprivation
Sleep deprivation is a more severe form of sleep loss...
The Availability Heuristic
Obedience
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...