Extraction and Digitization of ECG Signals from Standard Clinical Portable Document Format Files for the Principal
Michal Schäfer1, Max B Mitchell2, Caitlin Brateng3,4
1Division of Cardiology, Heart Institute, Children's Hospital Colorado, University of Colorado Denver, 13123 E 16th Ave, Anschutz Medical Campus, Aurora, CO, 80045-2560, USA. michal.schafer@cuanschutz.edu.
Introduction:
T-wave analysis from standard electrocardiogram (ECG) remains one of the most available clinical and research methods for evaluating myocardial repolarization. T-wave morphology was recently evaluated to aid with diagnosis and characterization of diastolic dysfunction. Unfortunately, PDF stored ECG datasets limit additional numerical post-processing of ECG waveforms. In this study, we apply a simple custom process pipeline to extract and re-digitize T-wave signals and subject them to principal component analysis (PCA) to define primary T-wave shape variations.
Methods:
We propose simple pre-processing and digitization algorithms programmable as a MATLAB tool using standard thresholding functions without the need for advanced signal analysis. To validate digitized datasets, we compared clinically standard measurements in 20 different ECGs with the original ECG machine interpreted values as a gold standard. Afterwards, we analyzed 212 individual ECGs for T-wave shape analysis using PCA.
Results:
The re-digitized signal was shown to preserve the original information as evidenced by excellent agreement between original - machine interpreted and re-digitized clinical variables including heart rate: bias ~ 1 bpm (95% CI: -1.0 to 3.5), QT interval: bias ~ 0.000 ms (95% CI: -0.012 to 0.012), PR interval: bias = -0.015 ms (95% CI: -0.015 to 0.003), and QRS duration: bias = -0.001 ms (95% CI: -0.007 to 0.006). PCA revealed that the first principal component universally modulates the T-wave height or amount of repolarization voltage regardless of the investigated ECG lead. The second and third principal components described variation in the T-wave peak onset and the T-wave peak morphology, respectively.
Conclusion:
This study presents a straightforward method for re-digitizing ECGs stored in the PDF format utilized in many academic electronic medical record systems. This process can yield re-digitized lead specific signals which can be retrospectively analyzed using advanced custom post-processing numerical analysis independent of commercially available platforms.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...