Related Experiment Video
Updated: Jul 20, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
An improved nonlinear deloading approach based on the fuzzy controller for wind turbine generators in an islanded
Akhilesh Kumar Mishra1, Puneet Mishra1, H D Mathur1
1Department of Electrical and Electronics Engineering, Birla Institute of Technology and Science, Pilani, Pilani Campus, Rajasthan, 333031, India.
Abstract:
The wind turbine generators (WTG's) incapability of primary frequency support during system contingencies due to its decoupled nature from the system frequency causes profound integration and stability issues. The present study focuses on resolving such issues by enabling the WTGs to participate in long-term frequency support under the derated operation of WTGs. The deloading operation of WTGs can provide a specific reserve power margin by reducing its rotor speed, which can be utilized during system contingencies. In literature, linear and quadratic deloading techniques have been proposed but these fail to replicate the nonlinear characteristics of the WTG accurately, thereby making deloading ineffective. To effectively implement the deloading, this work uses a more-accurate higher-order Newton's interpolation polynomial (HNIP), to cope with the highly nonlinear characteristics of WTG. The proposed deloading approach is also augmented with a fuzzy-based intelligent supplementary control structure to handle the inherent and incorporated nonlinearities in WTG. The microgrid system, consisting of a conventional energy source with WTG, has been considered as system under investigation. The integral time absolute error for step wind profile and variable speed wind profile was found to be improved by 97.65% and 97.29%, respectively, with the proposed novel deloading technique with fuzzy-PID compared to PID. Further, to ensure the implementation viability of the proposed control scheme, real-time validation of the same is carried out on OPAL-RT 4510, having a Xilinx Kintex-7 FPGA board. It was found that for all the scenarios considered for real-time digital simulation purposes, the results unerringly matched with MATLAB/Simulink.
More Related Videos
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Generator Voltage Control
Load-frequency control
Fast Decoupled and DC Powerflow
Turbine-Governor Control
Wind Turbine Machine Models
Induction machines interact through the rotating magnetic field generated by the stator and the rotor. The key parameter is slip, which is the difference between synchronous speed and rotor speed relative to synchronous speed. Slip is...
Control of Power Flow