Related Experiment Video
Updated: Jul 20, 2025

Continuous Telemetric In Utero Tracheal Pressure Measurements in Fetal Lambs
Published on: December 22, 2023
The prognosis of neonatal respiratory status within three years after birth in chronic abruption-oligohydramnios
Shoko Nishikawa1, Mana Taki1, Haruko Okamoto1
1Department of Gynecology and Obstetrics, Kyoto University Graduate School of Medicine, Kyoto, Japan.
Aim:
Chronic abruption-oligohydramnios sequence (CAOS), which is characterized by vaginal bleeding and oligohydramnios, adversely affects the lungs of fetuses due to bloody amniotic fluid and oligohydramnios. The criteria for termination of pregnancy remain controversial. This study aimed to examine respiratory function in infants within 3 years after birth and risk factors for respiratory prognosis, and to clarify the management of CAOS.
Methods:
This study is a case series of patients with CAOS managed at our institution between 2010 and 2020. The clinical data of the patients and their infants within 3 years after birth were reviewed. The amniotic fluid volume was measured using the maximum vertical pocket (MVP).
Results:
Six of 17 neonates (35.3%) used inhaled nitric oxide (iNO) to improve oxygenation. Women with longer periods of MVP <1 cm delivered more neonates using iNO; however, periods of MVP <2 cm were not associated with iNO use. Almost half of the infants required home oxygen therapy when discharged, regardless of amniotic fluid volume. At 18 months corrected age, only one child needed respiratory support, and the others discontinued. Two neonates, both born at 23 weeks of gestational age, died within 1 month after birth because of extremely preterm birth.
Conclusions:
The amniotic fluid volume could predict the use of iNO in neonates, but it did not affect the child's respiratory function after the newborn period. Almost all children born to women with CAOS can improve their respiratory function as they grow up.
More Related Videos
07:36Modeling Encephalopathy of Prematurity Using Prenatal Hypoxia-ischemia with Intra-amniotic Lipopolysaccharide in Rats
Published on: November 20, 2015
06:15Protocol and Guidelines for Point-of-Care Lung Ultrasound in Diagnosing Neonatal Pulmonary Diseases Based on International Expert Consensus
Published on: March 6, 2019
Related Concept Videos
Acute Respiratory Failure-III
Pulmonary Cycle: Exhalation
Acute Respiratory Failure-V
Ensure that patients are monitored continuously for their response to therapy, including changes in...
Acute Respiratory Failure-IV
Acute Respiratory Failure-II
The underlying physiological abnormalities that contribute to hypoxemic respiratory failure include:
Respiratory System Abnormal Finding I: Inspection and Percussion
Inspection Findings
During an inspection, several findings may suggest the presence of respiratory distress or disease. Pursed-lip breathing, where exhalation is slowed by...