Related Experiment Video
Updated: Feb 8, 2026

10:11
Expression of Exogenous Antigens in the Mycobacterium bovis BCG Vaccine via Non-genetic Surface Decoration with the Avidin-biotin System
Published on: January 31, 2018
9.8K
[Protection provided by BCG in university students]
Revista Clinica Espanola
|July 1, 1986
Summary
No abstract available in PubMed .
More Related Videos
06:32Protective Efficacy and Pulmonary Immune Response Following Subcutaneous and Intranasal BCG Administration in Mice
Published on: September 19, 2016
11.1K
08:10A Functional Whole Blood Assay to Measure Viability of Mycobacteria, using Reporter-Gene Tagged BCG or M.Tb BCG lux/M.Tb lux
Published on: September 14, 2011
14.2K
Related Concept Videos
Student t Distribution
14.2K
The population standard deviation is rarely known in many day-to-day examples of statistics. When the sample sizes are large, it is easy to estimate the population standard deviation using a confidence interval, which provides results close enough to the original value. However, statisticians ran into problems when the sample size was small. A small sample size caused inaccuracies in the confidence interval.
The Student t distribution was developed by William S. Goset (1876–1937) of the...
The Student t distribution was developed by William S. Goset (1876–1937) of the...
14.2K
Microsoft Excel: Student's t-Test
1.7K
Student's t-test in Microsoft Excel is a statistical method used to compare the means of two groups to determine if they are significantly different from each other. It's commonly used to evaluate hypotheses, such as testing whether a treatment has an effect compared to a control group. Excel provides built-in functions to perform t-tests, making it accessible for users needing to conduct basic statistical analysis.
To conduct a t-test in Excel, use the T.TEST function or the "Data...
To conduct a t-test in Excel, use the T.TEST function or the "Data...
1.7K
Comparing Experimental Results: Student's t-Test
6.1K
The t-test is a statistical method used to compare the sample mean with a population mean or compare two means from two data sets. The test statistic is calculated from the standard deviation, mean, and number of measurements in the data set at a selected confidence interval and then compared to a table of critical values at this confidence level. If the test statistic is smaller than the critical value, the null hypothesis is accepted. In this case, we state that the difference between the...
6.1K
Protection of Alcohols
8.1K
This lesson delves into the concept of protection and deprotection of a functional group fundamental to synthetic organic chemistry. These phenomena are explained in the context of aliphatic and aromatic alcohols.
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
8.1K
Zones of Protection
808
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
808
Radial System Protection
447
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
447