Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Imaging Studies II: Positron Emission Tomography and Scintigraphy01:25

Imaging Studies II: Positron Emission Tomography and Scintigraphy

153
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
153
Positron Emission Tomography01:29

Positron Emission Tomography

4.3K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
4.3K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[18F]FDG PET/CT in rheumatoid arthritis.

The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of...·2022
Same author

Prostate cancer bone metastases confined to the distal left lower limb.

Radiology case reports·2021
Same author

Interobserver Agreement in the Diagnosis of Parkinson Disease with Cardiac <sup>123</sup>I-Metaiodobenzylguanidine Scintigraphy.

Journal of nuclear medicine technology·2021
Same author

Pleural, pancreatic and prostatic involvement in IgG4-related disease mimicking pancreatic head malignancy.

BJR case reports·2020
Same author

<sup>18</sup>FDG-PET/CT findings in COVID-19: a single centre retrospective radiological review.

BJR case reports·2020
Same author

UK audit of glomerular filtration rate measurement from plasma sampling in 2013.

Nuclear medicine communications·2014

Related Experiment Video

Updated: Jul 17, 2025

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.4K

Technical concepts on blood pool phase SPECT (acquisition, reconstruction).

Sarah C Cade1, Richard N Graham2

  • 1Department of Medical Physics and Bioengineering - szarah.cade@nhs.net.

The Quarterly Journal of Nuclear Medicine and Molecular Imaging : Official Publication of the Italian Association of Nuclear Medicine (AIMN) [And] the International Association of Radiopharmacology (IAR), [And] Section of the Society Of
|August 30, 2023
PubMed
Summary

Early phase bone scintigraphy using SPECT/CT offers improved diagnostic value. Optimizing acquisition protocols, including rapid imaging and advanced reconstruction, enhances efficiency and accuracy for bone imaging.

More Related Videos

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.0K
Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
09:55

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules

Published on: October 4, 2024

451

Related Experiment Videos

Last Updated: Jul 17, 2025

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function
10:21

Continuous Blood Sampling in Small Animal Positron Emission Tomography/Computed Tomography Enables the Measurement of the Arterial Input Function

Published on: August 8, 2019

8.4K
A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
09:49

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods

Published on: April 24, 2020

10.0K
Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
09:55

Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules

Published on: October 4, 2024

451

Area of Science:

  • Nuclear Medicine
  • Radiology
  • Medical Imaging

Background:

  • Established bone scintigraphy guidelines recommend planar early phase imaging.
  • Advances in gamma camera technology enable early phase SPECT/CT imaging.
  • Current research on early phase SPECT/CT acquisition is limited.

Purpose of the Study:

  • To review the current state of early phase SPECT/CT bone imaging.
  • To explore areas for future investigation in early phase SPECT/CT.
  • To provide recommendations for adopting early phase SPECT/CT in clinical practice.

Main Methods:

  • Review of existing literature on early phase bone imaging with SPECT/CT.
  • Discussion of rapid SPECT imaging techniques using iterative reconstruction.
  • Consideration of CZT-based systems for improved sensitivity and resolution.
  • Investigation of projection measurement order optimization to reduce artifacts.

Main Results:

  • Iterative reconstruction algorithms can reduce SPECT imaging durations to as low as 4 minutes.
  • CZT-based systems offer potential for reduced imaging times due to higher sensitivity and resolution.
  • Optimizing projection order can mitigate artifacts from changing tracer distribution.

Conclusions:

  • Early phase SPECT/CT imaging holds potential for enhanced diagnostic confidence and prognostic value in bone scintigraphy.
  • Further optimization of acquisition protocols is needed for widespread clinical adoption.
  • Recommendations are provided for departments implementing early phase SPECT/CT blood pool imaging.