Related Experiment Video
Updated: Jul 17, 2025

Microfluidics in Assessing Platelet Function
Published on: November 8, 2024
Investigation of Platelet Function Analyzer 200 platelet function measurements in healthy cats and cats receiving
Matthew R Kornya1, Anthony C G Abrams-Ogg1, Shauna L Blois1
1Departments of Clinical Studies, Ontario Veterinary College, University of Guelph, Guelph, Ontario, Canada.
Abstract:
The Platelet Function Analyzer 200 (PFA-200; Siemens) is an in vitro substitute for in vivo bleeding time that is designed to investigate platelet function in a more physiologic manner than traditional aggregometry. The analyzer reports a closure time (CT) as a marker of platelet function, and may also report the calculated platelet function measurement primary hemostasis components, PHC1 and PHC2. These incorporate the measured total volume (TV) of blood aspirated and the initial flow rate (IF). We determined, for the COL/ADP and P2Y cartridges, the median total volume (TVmedian), and RIs for CT, IF, TV, PHC1, and PHC2, and investigated the sensitivity and specificity of those parameters at the determined interpretation thresholds in determination of the clopidogrel effect. Healthy client-owned cats were recruited prospectively to determine RIs for CT, IF, TV, PHC1, and PHC2. Healthy blood-donor cats and cats on clopidogrel therapy were included retrospectively to determine test performance. In 20 healthy cats, RIs for COL/ADP were CT (19.5-87.2 s), IF (199-278 µL/min), TV (199-332 µL), PHC1 (94-106%), and PHC2 (52-148%); and for P2Y, CT (4.2-94.3 s), IF (112-208 µL/min), TV (151-294 µL), PHC1 (35-178%), and PHC2 (90-109%). CVs were calculated for all of these values. Specificity for detection of the clopidogrel effect was calculated from a group of healthy blood donors, and sensitivity for detection of the clopidogrel effect from a group of cats with known clopidogrel effect. Sensitivity and specificity were, for COL/ADP: CT (83.3%, 66.6%), IF (41.4%, 83.3%), TV (83.3%, 100%), PHC1 (100%, 100%) and PHC2 (100%, 83.3%); and for P2Y: CT (100%, 94.4%), IF (30%, 44.4%), TV (100%, 94.4%), PHC1 (100%, 100%), and PHC2 (100%, 97.7%). These PFA-200 values may be beneficial in the determination of platelet function in cats.
More Related Videos
05:49Procoagulant Platelet Characterization by Measuring Phosphatidylserine Exposure and Microvesicle Release from Human Purified Platelets
Published on: November 29, 2024
04:37Comprehensive Analysis of Procoagulant Platelets Exhibiting Features of Necrosis, Apoptosis and Platelet Activation
Published on: May 23, 2025
Related Concept Videos
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
Structure and Function of Platelets
Platelets are continually replenished, circulating in the bloodstream for 9-12 days before being removed by phagocytes, primarily in the spleen. A microliter of circulating blood contains between 150,000 and 450,000...
Formation of the Platelet Plug
As the injured blood vessel contracts, endothelial cells undergo contraction, revealing collagen fibers in the basement membrane and underlying connective tissue. Furthermore, the plasma membrane of endothelial cells becomes adhesive, preparing the site for platelet adhesion. Platelets...