The biomechanical stability of miniplate osteosynthesis configurations in bilateral mandibular angle fractures
Nida Ay1, Senem Yildirimturk Dogan2, Yigit Sirin2
1Graduate School of Health Sciences, Department of Oral and Maxillofacial Surgery, Istanbul University.
Purpose:
The present study investigated the biomechanical stability of three miniplate osteosynthesis configurations used for internal fixation of bilateral mandibular angle fracture (BMAF).
Methods:
Standard fracture lines were created in 72 polyurethane mandibles and stabilized with 2.0-mm, 4-hole standard titanium miniplates and monocortical screws. The group descriptions and miniplate configurations were: 2Plates (1-1), 3Plates (1-2) and 4Plates (2-2). The mandibles were subjected to either incisal or molar loads (from both sides in the 3Plates group) up to a force of 120 N. The displacements of the constructs were recorded at each force increment of 10 N. ANOVA and Tukey's post-hoc tests were used for statistical analysis.
Results:
The 2Plates group showed higher displacement under both loading conditions (P < 0.05 for each). The same group reached displacement levels of 1 mm and 3 mm during molar loading and 1 mm, 3 mm, and 5 mm during incisal loading at lower force magnitudes relative to others (P < 0.05 for each).
Conclusion:
Bone-plate constructs for BMAFs stabilized with three or four standard miniplates are more likely to provide similar resistance when subjected to incisal or molar loads, in contrast to the two-miniplate configuration, which is relatively more prone to displacement.
More Related Videos
05:45Author Spotlight: Exploring Regeneration in Axolotls Through Insights in Cellular and Molecular Mechanisms, Bone Healing, and Implications for Human Therapies
Published on: April 12, 2024
04:13Less-Invasive Technique for Non-stabilized Mandibular Fracture in Mouse Models
Published on: September 27, 2024
Related Concept Videos
Bone Structure
Bone Remodeling
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Deformation of Member under Multiple Loadings
In the case of a member with a variable cross-section, the strain is not constant but depends on the position. The deformation of an...
Plastic Deformations of Members with a Single Plane of Symmetry
Stability of structures