Related Experiment Video
Updated: Jul 16, 2026

A Simple Device to Rapidly Prepare Whole Mounts of the Mouse Intestine
Published on: October 27, 2015
Determining the Possibilities of Reducing Visible Quality Defects in Commercial Elements of Turkey Carcasses Using an
Joanna Katarzyna Banach1, Ryszard Żywica1, Małgorzata Grzywińska-Rąpca2
1Institute of Management and Quality Sciences, Faculty of Economics, University of Warmia and Mazury in Olsztyn, 10-719 Olsztyn, Poland.
Abstract:
The development of the quality and commercial value of poultry meat is related to the formation of visible quality defects (hemorrhages) in muscles during the first stage of production (stunning). The production of meat with an unusual appearance for the consumers affects their purchasing decisions and, consequently, the company's economics. The aim of this research was to determine the possibility of reducing visible quality defects (large and small hemorrhages) in commercial turkey carcass elements (fillet, loin, wing) using an alternative device (AD) for the electrical stunning of animals in comparison to the quality effects obtained using the conventional device (CD) in plant X. The factors differentiating the experiment were the electrical current frequency (AD: 125, 400, 800, and 1600 Hz; CD: 50 Hz) and process time (9 and 18 s). The increase in electrical current frequency used in the alternative device stunner (own construction) resulted in changing the percentage share of defective turkey meat production. The greatest reduction of minor and severe meat defects and improvement of its quality were obtained for the alternative device at f = 800 Hz and t = 9 s-considered optimal for specific industrial conditions. Extending the time of stunning turkeys to 18 s had a positive effect on visible quality defects in the evaluated commercial elements of the carcass; however, its application in practice will depend on the efficiency of the slaughter line of the plant. A comparative analysis of the results of the impact of the frequency of electric current in the alternative device and plant X on the improvement of meat quality showed a justified need to commercialize the research results and replace the device currently used in the plant with an alternative one.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
04:36Vacuum-Sealed Hot Water Bath Immersion for the Preparation of Anatomical and Surgical Cadaveric Bone Models
Published on: December 2, 2022
Related Concept Videos
Prevention of Further Absorption of Poison
CNS Depressants: Alcohol and Nicotine
Pharmaceutical Poisoning: Potential Scenarios
Pharmaceutical Poisoning: Treatment Strategies
Depressants
Alcohol is a common depressant that can induce a sense of relaxation and reduced inhibition at low doses. Contrary to its occasional...