Related Experiment Video
Updated: Jul 16, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Computer and experimental analysis of a reconfigurable staircase module-based multi-level inverter with fault
Reza Choupan Ebrahimabad1, Daryoush Nazarpour1, Sajjad Golshannavaz1
1Electrical and Computer Engineering Department, Urmia University, 11km SERO Road, Urmia, Iran.
Abstract:
In the conventional multilevel inverters, occurrence of a fault in one or more power switches can cause abnormal changes in the output waveforms. Besides, increasing the applied power switches results to an increase in the possibility of fault on the power switches. Accordingly, providing a comprehensive structure with high fault-tolerant capability is one of the vital requirements and critical challenges. To tackle these issues, this study first presents and explores a new basic unit and staircase module (SM) and then extends and optimizes it to yield a reconfigurable multi-level inverter (MLI) with more levels and different goals. The proposed MLI can continue to operate when open-circuit faults in switches. This advantage of the proposed structure is achieved without any redundant legs or switches. For further investigation, a comparison is made in terms of the number of power switches, drivers, dc sources, and reliability between the proposed and similar structures. To control the output voltage levels, the strategy of fundamental frequency switching triggers the configured topology. The carrier signals are reconfigured under fault conditions based on levels to be generated by bypassing the faulted switch. The validity of the established MLI with its fault-tolerant capability is certified through both computer simulations using the MATLAB/Simulink platform and laboratory prototype implementations.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
Related Concept Videos
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
Bus Impedance Matrix
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
Power System Three-Phase Short Circuits
Fault Types
For line-to-line faults occurring between phases B and C, the...
Voltage Doubler Circuit
Reclosers and Fuses