Noise Reduction of Low-Count STEM-EDX Data by Low-Rank Regularized Spectral Smoothing

Keisuke Ozawa1

  • 1DENSO IT Laboratory, Research and Development Group, Tokyo, Japan.

Related Concept Videos

Downsampling01:20

Downsampling

When considering a sampled sequence with zero values between sampling instants, one can replace it by taking every N-th value of the sequence. At these integer multiples of N, the original and sampled sequences coincide. This process, known as decimation, involves extracting every N-th sample from a sequence, thereby creating a more efficient sequence.
The Fourier transform of the decimated sequence reveals a combination of scaled and shifted versions of the original spectrum. This...
177
Upsampling01:22

Upsampling

Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
254
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
719
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
2.4K
¹³C NMR: ¹H–¹³C Decoupling01:04

¹³C NMR: ¹H–¹³C Decoupling

The probability of having two carbon-13 atoms next to each other is negligible because of the low natural abundance of carbon-13. Consequently, peak splitting due to carbon-carbon spin-spin coupling is not observed in spectra. However, protons up to three sigma bonds away split the carbon signal according to the n+1 rule, resulting in complicated spectra.
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
1.1K
Quantifying and Rejecting Outliers: The Grubbs Test01:02

Quantifying and Rejecting Outliers: The Grubbs Test

Sometimes, a data set can have a recorded numerical observation that greatly  deviates from the rest of the data. Assuming that the data is normally distributed, a statistical method called the Grubbs test can be used to determine whether the observation is truly an outlier.  To perform a two-tailed Grubbs test, first, calculate the absolute difference between the outlier and the mean. Then, calculate the ratio between this difference and the standard deviation of the sample. This...
1.6K